is not exceeded. In case the insulating resistance measurement is technically impossible, because
controller contacts or relays are only active when mains voltage is applied, the protective conductor
current shall be tested by means of the present appliance tester and the direct or differential cur-
rent measurement method. For medical electrical devices, IT devices or SELV-carrying parts, the
measurement may be omitted, if damages can occur due to adaptation or insulating voltage (see
operating manual of the test sample!).
By pressing the <Pause> button, it is possible to interrupt measurement so that e.g. the test cable
with the alligator clip can be connected to another measuring point without resulting in incorrect
measurements / indications. Delete the measured value by pressing <Reset>. By means of the
setup program, it is possible to set the testing voltage of the device to lower values (50-500 V DC,
beyond the standard).
Attention! Pressing the <Pause> button will stop the measurement. During the pause,
the test socket will remain live!
BENNING ST 750 A
24 / 68
M
G
L N
1
2
4
ST 750A
PE
3
Sonde
Isolationswiderstand R
ISO
:
DIN VDE 0701-0702 (SK I)
ST 750A Gerätetester
1 Ohmmeter (MΩ)
2 Generator (DC 500V)
3 Prüfling
4 Prüfsteckdose
M
G
L
N
5
1
2
6
3
4
Sonde
ST 750A
Isolationswiderstand R
ISO
:
DIN VDE 0701-0702 (SK II)
ST 750A Gerätetester
1 Ohmmeter (MΩ)
2 Generator (DC 500V)
3 Buchse, „Sonde“
4 Prüfleitung mit Tastspitze
5 Prüfling
6 Prüfsteckdose
M
G
5
1
2
6
U < 50 V AC
U < 120V DC
3
4
Sonde
ST 750A
Isolationswiderstand R
ISO
:
DIN VDE 0701-0702 (SK III)
ST 750A Gerätetester
1 Ohmmeter (MΩ)
2 Generator (DC 500V)
3 Buchse, „Sonde“
4 Prüfleitung mit Tastspitze
5 Prüfling
6 Prüfsteckdose
M
G
L
N
1
2
6
PE
3
5
Sonde
4
ST 750A
Isolationswiderstand R
ISO
:
DIN VDE 0701-0702 (SK I mit
Stromausgang)
ST 750A Gerätetester
1 Ohmmeter (MΩ)
2 Generator (DC 500V)
3 Buchse, „Sonde“
4 Prüfleitung mit Tastspitze
5 Prüfling
6 Prüfsteckdose
M
G
L
N
1
2
6
3
5
Sonde
4
PE-Buchse
ST 750A
Isolationswiderstand R
ISO
:
DIN VDE 0701-0702 (SK II mit
Stromausgang)
ST 750A Gerätetester
1 Ohmmeter (MΩ)
2 Generator (DC 500V)
3 Buchse, „Sonde“
4 Buchse, „PE“
5 Prüfling
6 Prüfsteckdose
M
G
L N
1
2
5
PE
4
MP
AP
Sonde
3
ST 750A
Isolationswiderstand R
ISO
:
DIN VDE 0751-1 (SK I)
ST 750A Gerätetester
1 Ohmmeter (MΩ)
2 Generator (DC 500V)
3 Buchse, „Sonde“
4 Prüfling
5 Prüfsteckdose
M
G
L N
1
2
5
4
MP
AP
Sonde
3
ST 750A
Isolationswiderstand R
ISO
:
DIN VDE 0751-1 (SK I)
ST 750A Gerätetester
1 Ohmmeter (MΩ)
2 Generator (DC 500V)
3 Buchse, „Sonde“
4 Prüfling
5 Prüfsteckdose
Insulating resistance RInsu:
DIN VDE 0701-0702 (protection class I)
BENNING ST 750 A Appliance Tester
1 ohmmeter(MΩ)
2 generator (DC 500V)
3 test sample
4 test socket
BENNING ST 750 A
24 / 68
M
G
L N
1
2
4
ST 750A
PE
3
Sonde
Isolationswiderstand R
ISO
:
DIN VDE 0701-0702 (SK I)
ST 750A Gerätetester
1 Ohmmeter (MΩ)
2 Generator (DC 500V)
3 Prüfling
4 Prüfsteckdose
M
G
L
N
5
1
2
6
3
4
Sonde
ST 750A
Isolationswiderstand R
ISO
:
DIN VDE 0701-0702 (SK II)
ST 750A Gerätetester
1 Ohmmeter (MΩ)
2 Generator (DC 500V)
3 Buchse, „Sonde“
4 Prüfleitung mit Tastspitze
5 Prüfling
6 Prüfsteckdose
M
G
5
1
2
6
U < 50 V AC
U < 120V DC
3
4
Sonde
ST 750A
Isolationswiderstand R
ISO
:
DIN VDE 0701-0702 (SK III)
ST 750A Gerätetester
1 Ohmmeter (MΩ)
2 Generator (DC 500V)
3 Buchse, „Sonde“
4 Prüfleitung mit Tastspitze
5 Prüfling
6 Prüfsteckdose
M
G
L
N
1
2
6
PE
3
5
Sonde
4
ST 750A
Isolationswiderstand R
ISO
:
DIN VDE 0701-0702 (SK I mit
Stromausgang)
ST 750A Gerätetester
1 Ohmmeter (MΩ)
2 Generator (DC 500V)
3 Buchse, „Sonde“
4 Prüfleitung mit Tastspitze
5 Prüfling
6 Prüfsteckdose
M
G
L
N
1
2
6
3
5
Sonde
4
PE-Buchse
ST 750A
Isolationswiderstand R
ISO
:
DIN VDE 0701-0702 (SK II mit
Stromausgang)
ST 750A Gerätetester
1 Ohmmeter (MΩ)
2 Generator (DC 500V)
3 Buchse, „Sonde“
4 Buchse, „PE“
5 Prüfling
6 Prüfsteckdose
M
G
L N
1
2
5
PE
4
MP
AP
Sonde
3
ST 750A
Isolationswiderstand R
ISO
:
DIN VDE 0751-1 (SK I)
ST 750A Gerätetester
1 Ohmmeter (MΩ)
2 Generator (DC 500V)
3 Buchse, „Sonde“
4 Prüfling
5 Prüfsteckdose
M
G
L N
1
2
5
4
MP
AP
Sonde
3
ST 750A
Isolationswiderstand R
ISO
:
DIN VDE 0751-1 (SK I)
ST 750A Gerätetester
1 Ohmmeter (MΩ)
2 Generator (DC 500V)
3 Buchse, „Sonde“
4 Prüfling
5 Prüfsteckdose
Insulating resistance RInsu:
DIN VDE 0701-0702 (protection class II)
BENNING ST 750 A Appliance Tester
1 ohmmeter(MΩ)
2 generator (DC 500V)
3 "Probe"jack
4 test cable with probe tip
5 test sample
6 test socket
BENNING ST 750 A
24 / 68
M
G
L N
1
2
4
ST 750A
PE
3
Sonde
Isolationswiderstand R
ISO
:
DIN VDE 0701-0702 (SK I)
ST 750A Gerätetester
1 Ohmmeter (MΩ)
2 Generator (DC 500V)
3 Prüfling
4 Prüfsteckdose
M
G
L
N
5
1
2
6
3
4
Sonde
ST 750A
Isolationswiderstand R
ISO
:
DIN VDE 0701-0702 (SK II)
ST 750A Gerätetester
1 Ohmmeter (MΩ)
2 Generator (DC 500V)
3 Buchse, „Sonde“
4 Prüfleitung mit Tastspitze
5 Prüfling
6 Prüfsteckdose
M
G
5
1
2
6
U < 50 V AC
U < 120V DC
3
4
Sonde
ST 750A
Isolationswiderstand R
ISO
:
DIN VDE 0701-0702 (SK III)
ST 750A Gerätetester
1 Ohmmeter (MΩ)
2 Generator (DC 500V)
3 Buchse, „Sonde“
4 Prüfleitung mit Tastspitze
5 Prüfling
6 Prüfsteckdose
M
G
L N
1
2
6
PE
3
5
Sonde
4
ST 750A
Isolationswiderstand R
ISO
:
DIN VDE 0701-0702 (SK I mit
Stromausgang)
ST 750A Gerätetester
1 Ohmmeter (MΩ)
2 Generator (DC 500V)
3 Buchse, „Sonde“
4 Prüfleitung mit Tastspitze
5 Prüfling
6 Prüfsteckdose
M
G
L
N
1
2
6
3
5
Sonde
4
PE-Buchse
ST 750A
Isolationswiderstand R
ISO
:
DIN VDE 0701-0702 (SK II mit
Stromausgang)
ST 750A Gerätetester
1 Ohmmeter (MΩ)
2 Generator (DC 500V)
3 Buchse, „Sonde“
4 Buchse, „PE“
5 Prüfling
6 Prüfsteckdose
M
G
L N
1
2
5
PE
4
MP
AP
Sonde
3
ST 750A
Isolationswiderstand R
ISO
:
DIN VDE 0751-1 (SK I)
ST 750A Gerätetester
1 Ohmmeter (MΩ)
2 Generator (DC 500V)
3 Buchse, „Sonde“
4 Prüfling
5 Prüfsteckdose
M
G
L N
1
2
5
4
MP
AP
Sonde
3
ST 750A
Isolationswiderstand R
ISO
:
DIN VDE 0751-1 (SK I)
ST 750A Gerätetester
1 Ohmmeter (MΩ)
2 Generator (DC 500V)
3 Buchse, „Sonde“
4 Prüfling
5 Prüfsteckdose
Insulating resistance RInsu:
DIN VDE 0701-0702 (protection class III)
BENNING ST 750 A Appliance Tester
1 ohmmeter(MΩ)
2 generator (DC 500V)
3 "Probe"jack
4 test cable with probe tip
5 test sample
6 test socket
BENNING ST 750 A
24 / 68
M
G
L N
1
2
4
ST 750A
PE
3
Sonde
Isolationswiderstand R
ISO
:
DIN VDE 0701-0702 (SK I)
ST 750A Gerätetester
1 Ohmmeter (MΩ)
2 Generator (DC 500V)
3 Prüfling
4 Prüfsteckdose
M
G
L
N
5
1
2
6
3
4
Sonde
ST 750A
Isolationswiderstand R
ISO
:
DIN VDE 0701-0702 (SK II)
ST 750A Gerätetester
1 Ohmmeter (MΩ)
2 Generator (DC 500V)
3 Buchse, „Sonde“
4 Prüfleitung mit Tastspitze
5 Prüfling
6 Prüfsteckdose
M
G
5
1
2
6
U < 50 V AC
U < 120V DC
3
4
Sonde
ST 750A
Isolationswiderstand R
ISO
:
DIN VDE 0701-0702 (SK III)
ST 750A Gerätetester
1 Ohmmeter (MΩ)
2 Generator (DC 500V)
3 Buchse, „Sonde“
4 Prüfleitung mit Tastspitze
5 Prüfling
6 Prüfsteckdose
M
G
L
N
1
2
6
PE
3
5
Sonde
4
ST 750A
Isolationswiderstand R
ISO
:
DIN VDE 0701-0702 (SK I mit
Stromausgang)
ST 750A Gerätetester
1 Ohmmeter (MΩ)
2 Generator (DC 500V)
3 Buchse, „Sonde“
4 Prüfleitung mit Tastspitze
5 Prüfling
6 Prüfsteckdose
M
G
L
N
1
2
6
3
5
Sonde
4
PE-Buchse
ST 750A
Isolationswiderstand R
ISO
:
DIN VDE 0701-0702 (SK II mit
Stromausgang)
ST 750A Gerätetester
1 Ohmmeter (MΩ)
2 Generator (DC 500V)
3 Buchse, „Sonde“
4 Buchse, „PE“
5 Prüfling
6 Prüfsteckdose
M
G
L N
1
2
5
PE
4
MP
AP
Sonde
3
ST 750A
Isolationswiderstand R
ISO
:
DIN VDE 0751-1 (SK I)
ST 750A Gerätetester
1 Ohmmeter (MΩ)
2 Generator (DC 500V)
3 Buchse, „Sonde“
4 Prüfling
5 Prüfsteckdose
M
G
L N
1
2
5
4
MP
AP
Sonde
3
ST 750A
Isolationswiderstand R
ISO
:
DIN VDE 0751-1 (SK I)
ST 750A Gerätetester
1 Ohmmeter (MΩ)
2 Generator (DC 500V)
3 Buchse, „Sonde“
4 Prüfling
5 Prüfsteckdose
Insulating resistance RInsu:
DIN VDE 0701-0702 (protection class I with
current output)
BENNING ST 750 A Appliance Tester
1 ohmmeter(MΩ)
2 generator (DC 500V)
3 "Probe"jack
4 test cable with probe tip
5 test sample
6 test socket
BENNING ST 750 A
24 / 68
M
G
L N
1
2
4
ST 750A
PE
3
Sonde
Isolationswiderstand R
ISO
:
DIN VDE 0701-0702 (SK I)
ST 750A Gerätetester
1 Ohmmeter (MΩ)
2 Generator (DC 500V)
3 Prüfling
4 Prüfsteckdose
M
G
L
N
5
1
2
6
3
4
Sonde
ST 750A
Isolationswiderstand R
ISO
:
DIN VDE 0701-0702 (SK II)
ST 750A Gerätetester
1 Ohmmeter (MΩ)
2 Generator (DC 500V)
3 Buchse, „Sonde“
4 Prüfleitung mit Tastspitze
5 Prüfling
6 Prüfsteckdose
M
G
5
1
2
6
U < 50 V AC
U < 120V DC
3
4
Sonde
ST 750A
Isolationswiderstand R
ISO
:
DIN VDE 0701-0702 (SK III)
ST 750A Gerätetester
1 Ohmmeter (MΩ)
2 Generator (DC 500V)
3 Buchse, „Sonde“
4 Prüfleitung mit Tastspitze
5 Prüfling
6 Prüfsteckdose
M
G
L
N
1
2
6
PE
3
5
Sonde
4
ST 750A
Isolationswiderstand R
ISO
:
DIN VDE 0701-0702 (SK I mit
Stromausgang)
ST 750A Gerätetester
1 Ohmmeter (MΩ)
2 Generator (DC 500V)
3 Buchse, „Sonde“
4 Prüfleitung mit Tastspitze
5 Prüfling
6 Prüfsteckdose
M
G
L
N
1
2
6
3
5
Sonde
4
PE-Buchse
ST 750A
Isolationswiderstand R
ISO
:
DIN VDE 0701-0702 (SK II mit
Stromausgang)
ST 750A Gerätetester
1 Ohmmeter (MΩ)
2 Generator (DC 500V)
3 Buchse, „Sonde“
4 Buchse, „PE“
5 Prüfling
6 Prüfsteckdose
M
G
L N
1
2
5
PE
4
MP
AP
Sonde
3
ST 750A
Isolationswiderstand R
ISO
:
DIN VDE 0751-1 (SK I)
ST 750A Gerätetester
1 Ohmmeter (MΩ)
2 Generator (DC 500V)
3 Buchse, „Sonde“
4 Prüfling
5 Prüfsteckdose
M
G
L N
1
2
5
4
MP
AP
Sonde
3
ST 750A
Isolationswiderstand R
ISO
:
DIN VDE 0751-1 (SK I)
ST 750A Gerätetester
1 Ohmmeter (MΩ)
2 Generator (DC 500V)
3 Buchse, „Sonde“
4 Prüfling
5 Prüfsteckdose
Insulating resistance RInsu:
DIN VDE 0701-0702 (protection class II with
current output)
BENNING ST 750 A Appliance Tester
1 ohmmeter(MΩ)
2 generator (DC 500V)
3 "Probe"jack
4 "PE"jack
5 test sample
6 test socket
probe
probe
probe
probe
jack PE
probe