Operation Manual

08/ 2012 39 / 58
BENNING ST 750 A
13. Internal / Automatic Test Procedures
The BENNING ST 750 A Appliance Tester supports automatic test procedures. At the time of de-
livery, it is provided with 26 preset test procedures. Moreover, the user can create or modify own
test procedures.
13.1 Internal Test Procedures for Devices according to VDE 0701/0702 (Protection Class I)
1 x x x x x
2 x x x x x
3 x x x x x x
4 x x x x x
5 x x x x x
6 x x x x x
7 x x x x x
8 x x x x x
9 x x x x
10 x x x x x
11 x x x x x x x x x
12 x x x x x
13 x x x x x
14 x x x x x x
15 x x x x x x
Device, Class I
Device, Class I with RPE 10 A
Device, Class I with ICont
Device, Class I without RPE + ICont
Device, Class I with heat. < 3.5 kW
Device, Class I with IPE (alt.)
Device, Class I, RPE 10 A + IPE (alt.)
Device, Class I with RInsu 250 V
Device, Class I without RInsu
Device, Class I without RInsu + ICont
Device, Class I with sec. U-output
Device, Class I with IPE (clamp)
Device, Class I, RPE 10 A + IPE (clamp)
Line, shock-proof
Line, shock-proof, RInsu 250 V
A
ut
oma
t
i
c
T
e
s
t
No.
B
E
NNI
NG
S
T
750
A
B
r
i
ef
Des
c
r
i
pt
ion
V
i
s
ual
I
ns
p
ec
t
ion
C
o
nnec
t
i
on
T
e
s
t
R
P
E
@
200
mA
R
P
E
@
10
A
R
I
ns
u
-
1:
L/
N
-
P
E
R
I
ns
u-
1:
L/
N
-
P
E
@
0.
3
M
Ω
R
I
ns
u-
1:
L/
N
-
P
E
@
250
V
R
I
ns
u-
2:
s
e
c
.
-
P
E
R
I
ns
u-
3:
L/
N
-
s
e
c
.
I
P
E
(
al
t
.
)
I
P
E
(
c
lamp
)
I
Cont
(
d
i
r
.
)
F
u
n
c
t
ion
a
l
T
e
s
t
L
ine
U
a
S
a
f
e
t
y
Ex
t
r
a
-
L
o
w
Vo
l
t
a
g
e
1
Device of Class I with RPE (200 mA), RInsu (500 V), functional test with IPE (differen-
tial current measurement, probe switched off)
2
Device of Class I with RPE (10 A), RInsu (500 V), functional test with IPE (differential
current measurement, probe switched off)
3
Device of Class I with RPE (200 mA), RInsu (500 V), ICont (direct), functional test with
IPE (differential current measurement, probe switched off)
4
Device of Class I with functional earth, without RPE, RInsu (500 V), ICont directly, e.g.
completely insulated coffee machine with PE connector (Class I) without accessible
PE contact
5
DeviceofClassIwithheatingelementsP<3.5kW,RInsu(500V,R>0.3MΩ),functional
test incl. IPE (differential current measurement, probe switched off)
6
Device of Class I with RPE (200 mA), RInsu (500V), IPE (alternative measurement),
no functional test, for measurement of heating devices. devices without switch-mode
power supplies, three-phase devices via adapter 044122 / 044123
7
Device of Class I with RPE (10 A), RInsu (500V), IPE (alternative measurement), for
testing extension cables up to 5 m or tools with 300 Hz such as power screwdrivers,
grinding tools etc.
8
Device of Class I with overvoltage arresters with RPE (200 mA), RInsu (250 V), func-
tional test with IPE (differential current measurement, probe switched off)
9
Device of Class I with RPE (200 mA), without RInsu, functional test with IPE (diffe-
rential current measurement, probe switched off), test procedure without RInsu, only
withjustication
10
Device of Class I with RPE (200 mA), without RInsu, ICont (direct measurement),
functional test with IPE (differential current measurement, probe switched off), test
procedurewithoutRInsu,onlywithjustication
11
Device of Class I with RPE (200mA), 3 x RInsu(500V), ICont (direct measurement),
functional test incl. IPE (differential current measurement, probe switched off), Ua at
secondary output, e.g. mains supply units, chargers
12
Three-phase device of Class I via adapter 044122/044123: RPE (200 mA) + RInsu
(500V) by means of CM 9 and adapter 044127/044128: IPE (clamp measurement)
13
Three-phase device of Class I via adapter 044122/044123: RPE (10 A) + RInsu (500V)
by means of CM 9 and adapter 044127/044128: IPE (clamp measurement)
14
Shock-proof cable 16 A, RPE (200mA) limiting value from (l/A), preset length l=5m,
cross-section A=1.5 mm
2
,overallresistance:0,3Ω,per7.5m/0.1Ω,max.1Ω,RInsu
(500V), IPE (alternative measurement), line test
15
Shock-proof cable 16 A and overvoltage arrester, RPE (200mA) overall resistance
from (l/A), preset length l=5 m, cross-section A=1.5 mm
2
,overallresistance:0,3Ω,per
7.5m/0.1Ω,max.1Ω,RInsu(250V),IPE(alternativemeasurement),linetest