Operation Manual

06/ 2014
TRITEST
®
pro
4
Note:
Phase sequence tests can be carried out even with
the batteries being removed or exhausted.
5. LED torch
Warning!
Potentiallydangerousopticalradiation!
Do not look directly or indirectly via
reflecting surfaces into the LED beam!
Dangertoyourretina!
- The device is provided with a high-power LED
torch
6
with can be switched on and off by press-
ing the push-button
7
.
6. Batteryreplacement
- Do not apply voltage to the device when the bat-
tery compartment is open!
- The battery compartment is located on the back of
the device.
- Slightly press down the catch by means of a
screwdriver and push off the battery compartment
cover in downward direction at the same time.
- Replace the exhausted batteries by three new
ones of type AA (LR06). Make sure that the new
batteries are inserted with correct polarity!
- Push the battery compartment cover back onto
the housing until the catch locks into place with
an audible click.
Note:
The battery compartment cover is provided with an
integrated magnet and a belt clip for attachment of the
device.
7. Technical data
- Regulations: DIN EN 61010-1 and -031, IEC
61010-1 and -31, DIN EN 61557-1 and -7, IEC
61557-1 and -7, DIN EN 62471
- Nominal voltage range: 300 V to 500 V
- Measuring category: CAT III 300 V to earth
- Nominal frequency range f: 50 Hz / 60 Hz
- Current consumption: I
s
< 3.5 mA (500 V)
- Contamination level: 2
- Protection category: IP 40 (DIN VDE 0470-1 IEC /
EN 60529)
4 - first index: protection against access to dan-
gerous parts and protection against solid impuri-
ties of a diameter > 1.0 mm
0 - second index: no protection against water
- Battery: 3 x 1.5 V batteries of type AA (LR06)
- Weight: approx. 250 g
- Measuring line with test handles: length of approx.
1,000 mm
- Operating temperature range: - 15 °C to + 55 °C
- Storage temperature range: - 15 °C to + 55 °C
- Relative air humidity: 20 % to 80 %
8. General maintenance
Clean the exterior of the device with a clean dry cloth.
If there is contamination or deposits in the area of the
battery or the battery housing, clean these areas as
well by means of a dry cloth.
If the device is stored for a longer period of time,
remove the batteries from the device!
9. Environmental protection
At the end of product life, dispose of the
unserviceable device as well as used batte-
ries via appropriate collecting facilities provi-
ded in your community.