User's Manual
Table Of Contents
15 Installation
LK953ST
Screen size Distance from screen (mm)
Diagonal
W (mm) H (mm)
Min length
Average
Max length
Inch mm (max. zoom) (min. zoom)
30 762 664 374 538 565 591
40 1016 886 498 717 753 788
50 1270 1107 623 897 941 985
60 1524 1328 747 1076 1129 1182
80 2032 1771 996 1435 1505 1576
90 2286 1992 1121 1614 1694 1773
100 2540 2214 1245 1793 1882 1970
110 2794 2435 1370 1972 2070 2167
120 3048 2657 1494 2152 2258 2364
130 3302 2878 1619 2331 2446 2561
140 3556 3099 1743 2510 2634 2758
150 3810 3321 1868 2690 2823 2955
160 4064 3542 1992 2869 3011 3152
170 4318 3763 2117 3048 3199 3349
180 4572 3985 2241 3228 3387 3547
190 4826 4206 2366 3407 3575 3744
200 5080 4428 2491 3586 3763 3941
250 6350 5535 3113 4483 4704 4926
300 7620 6641 3736 5380 5645 5911
• To optimize your projection quality, we suggest you do the projection within non-gray area.
• All measurements are approximate and may vary from the actual sizes.
BenQ recommends that if you intend to permanently install the projector, you should physically test the
projection size and distance using the actual projector in situ before you permanently install it, so as to make
allowance for this projector's optical characteristics. This will help you determine the exact mounting position so
that it best suits your installation location.
• Ceiling installation must be done by a qualified professional. Contact your dealer for more information. It is not
recommended you install the projector yourself.
• Only use the projector on a solid, level surface. Serious injury and damage can occur if the projector is dropped.
• Do not use the projector in an environment where extreme temperature occurs. The projector must be used at
temperatures between 32 degrees Fahrenheit (0 degrees Celsius) and 104 degrees Fahrenheit (40 degrees
Celsius).
• Screen damage will occur if the projector is exposed to moisture, dust or smoke.
• Do not cover the vents on the projector. Proper ventilation is required to dissipate heat. Damage to the projector
will occur if the vents are covered.