Data Sheet

Waveform Display
Number of
samples
1,024; 2,048; 4,096; 8,192; 16,384;
32,768
Channels
220
max
samples
240
max
samples
1 16,384 32,768
2 8,192 16,384
3 or 4 N/A 8,192
Time
scale
10 ms to 256 seconds or orders
based from 1 to 999 revs
Balancing
Planes 2 planes, 2 sensors
Speed Range 3 to 12,000 RPM
Measurement
Type
Acceleration, Velocity,
Displacement
Weight modes Angle to 360°
Fixed Positions
Remove Trial
Weights
Yes/No
Automatic recalculation
Storage Balance jobs stored on
handheld and transferable
to System 1
Communication
Bluetooth BT 4.0 Classic
Battery and Charger
Battery type
Custom Lithium Ion pack, 7.4,
4000 mAh.
Not user accessible but
factory replaceable.
Operating
Time
10 hours typical on-route data
collection
Charger type
Internal charging, automatic
control.
External power pack 12 V DC, 3
A output.
Charge rate
2 A nominal 3 hours for
complete charge.
Mechanical
Size
5.1” W x 5.1” L x 1.4” H
(130 mm Wx 130 mm Lx 35
mm H
Weight 1.5 lb 680g
Environmental Limits
Operating
temperature
-4°F to 140°F (-20 to 60°C)
122°F (50°C) max when used
in Ex hazardous areas
Ambient
temperature
for charging
battery
32°F to 77°F (0°C to 25°C)
Storage
temperature
& humidity
-4°F to 140°F (-20°C to 60°C),
95%relative humidity If
storage exceeds one month:
up to 95°F (35°C), 85% relative
humidity.
Ruggedness
drop &
sealing
Drop spec MIL-STD-810F-
516.5-IV 26 drops at 4' (1.2 m)
onto concrete
IP65
SCOUT220-IS and SCOUT240-IS Portable Data Collectors
Datasheet 109M0226 Rev. Y
5/14
DRAFT