Instruction Manual

If there is an obstruction detected in the barrel, qualified
personnel (for example, a gunsmith) must remove the
obstruction and inspect the firearm before it can be fired.
DISASSEMBLY OF THE BOLT GROUP
Notice: Only disassemble the bolt group if the firing pin or
extractor need to be replaced. For cleaning and maintenance it
is not necessary to disassemble the bolt group.
• Press the bolt cover pin from right to left with the help of a
punch or a small screwdriver (Fig. 14). The pin is held in
position by a small metal spring inside the bolt cover.
• Now lift off the bolt cover from the bolt. Be careful as Spring-
loaded parts might pop out.
The firing pin and the extractor are now free and can easily be
replaced.
Notice: Further disassembly is not necessary or
recommended.
REASSEMBLY
Reassembly works in the reverse order of the procedures
described under DISASSEMBLY.
REASSEMBLY OF THE BOLT GROUP
To reassemble the bolt group put the firing pin and the firing pin
spring in position first. Then attach the bolt cover and fix it with
the bolt cover pin.
Insert the extractor spring, the extractor bolt and finally snap in
the extractor (Fig. 15).
Notice: Install the bolt cover pin from right to left. Installing from
left to right may damage the retaining spring.
20