Owner`s manual

83 | P a g e
Address
R/W
Name
Conversion
Notes
4147
R
NoDoubleClickTimer
[4142] Seconds
Forced time space between
manual MPPT sweeps.
4148
R/W
Battery output Current Limit
[4148] / 10) Amps
Battery Current Limit
Amps (example:
23.4 A = 234)
4149
R/W
Absorb Set Point Voltage
([4149] / 10) Volts
Battery Absorb Stage Set
point Voltage
(example: 28.3V = 283)
4150
R/W
Float Voltage Set Point
( [4150] / 10) Volts
Battery Float Stage Set
Point Voltage
4151
R/W
Equalize Voltage Set Point
([4151] / 10) Volts
Battery Equalize Stage Set
Point Voltage
4152
R
Sliding Current Limit
[4152] Amps
Sliding Current Limit
(changes with V/Temp etc.)
4153
R/W
Minimum Absorb Time
[4153] seconds
Minimum time for
Batteries to remain in
Absorb Stage.
4154
R/W
Maximum Absorb Time
[4154] seconds
Maximum time for
Batteries to remain in
Absorb Stage.
4155
R/W
Maximum Battery
Temperature Compensation
Voltage
([4155] / 10) Volts
Highest Charge Voltage is
limited to this value when
battery temp sensor
installed
4156
R/W
Minimum Battery
Temperature Compensation
Voltage
([4155] / 10) Volts
Lowest Charge Voltage is
limited to this value when
battery temp sensor
installed
4157
R/W
Battery Temp Comp Value
for each 2V cell
-([4157] / 10) mV/degree
C/cell (0.5 mV steps) 0 to 10
mV per 2V cell
Absolute value of the
Temperature Compensation
Value in mV/°C /2V cell
4158
R/W
Battery Type
[4158]
Type of Batteries. See
Table 4158-1
(unimplemented as of May
2011)
4159
RESERVED
4160
4161
W
Force Flag Bits
([4161] << 16) + [4160]
See Table 4160-1.