Owner`s manual

84 | P a g e
Address
R/W
Name
Conversion
Notes
4162
R/W
Equalize Time
[4162] Seconds
Initialize Time for Batteries
to remain in Equalize
Stage.
4163
R/W
Equalize Interval Days
[4163] Days
Number of days between
Equalize Stages (Auto EQ)
4164
R/W
Mppt Mode (Solar, Wind,
…………… etc)
[4164] (bit 0 = On/Off)
Maximum Power Point
Mode. See Table 4164-1.
4165
R/W
Aux 1 and 2 Function
[4165]
Combined Aux 1&2
Functions + On/Off. See
Table 4208
4166
R/W
Aux1VoltsLoAbs
([4166] /10) Volts
Aux 1 Absolute Low
Threshold Voltage
4167
R/W
Aux1DelayT
[4167] Milli Seconds
Aux 1 Delay time before
Asserting.
4168
R/W
Aux1HoldT
[4168] Milli Seconds
Aux 1 Hold time before
De-asserting.
4169
R/W
Aux2PwmVwidth
([4169] /10) Volts
Voltage range over which
PWM operates.
4170
RESERVED
4171
4172
R/W
Aux1VoltsHiAbs
([4172] /10) Volts
Aux 1 Absolute High Voltage
Threshold
4173
R/W
Aux2VoltsHiAbs
([4173] /10) Volts
Aux 2 Absolute High Voltage
Threshold
4174
R/W
Aux1VoltsLoRel (Relative to
charge stage set point V)
([4174] /10) Volts
Aux 1 Relative Lower
Voltage Threshold (Charge
Stage Rel)
4175
R/W
Aux1VoltsHiRel (Relative to
charge stage set point V)
([4175] /10) Volts
Aux 1 Relative Upper
Voltage Threshold (Charge
Stage Rel)
4176
R/W
Aux2VoltsLoRel (Relative to
charge stage set point V)
([4176] /10) Volts
Aux 2 Relative Lower
Voltage Threshold (Charge
Stage Rel)
4177
R/W
Aux2VoltsHiRel (Relative to
charge stage set point V)
([4177] /10) Volts
Aux 2 Relative Upper
Voltage Threshold (Charge
Stage Rel)
4178
R/W
Aux1VoltsLoPv (absolute)
([4178] /10) Volts
Aux 1 Lower PV Voltage
Threshold