Owner`s manual

88 | P a g e
Address
R/W
Name
Conversion
Notes
4251
R
BattMonSOC
4252
R
BattMonAmps
4253
R
BattMonAHefficiency
4254
RESERVED (Do NOT Write)
4255
4256
4257
R/W
RebulkTimerSec
[4257] seconds
Rebulk interval timer.
Cleared if Vbatt >= Rebulk
V
4258
4259
4260
4261
4262
4263
RESERVED (Do NOT Write)
4264
4265
Voc_Qualify_Timer_1ms
(([4265] << 16) + [4264])
msec
Timer (msec) qualifying time
till turn on valid (not 2
useful)
4266
R
MinVpvTurnOn
([4266] / 10) Volts
Minimum Turn On Volts(
Best Left Alone) Not too
useful
4267
RESERVED (Do NOT Write)
4268
4269
4270
4271
4272
R
RestartTimerms
[4271] Milli Seconds
Count Down Time until
Wake
Allowed
4273
R
Ibatt
([4272] /10) Amps
Battery Current, Unfiltered
4274
RESERVED (Do NOT Write)
4275
4276
R
ReasonForResting
[4275] Reason number
Reason Classic went to Rest
(See Table 4275-1)
4277
R
Output Vbatt
([4376] / 10) Volts
Battery Voltage Unfiltered
4278
R
Input Vpv
([4377] / 10) Volts
PV Voltage Unfiltered