Owner`s manual

89 | P a g e
4279
Address
R/W
Name
Conversion
Notes
4280
Typeint
([4279] << 16) + [4278]
TBD
4281
RESERVED (Do NOT Write)
4282
4283
Table 4101-1 Device Type
Name
Value
Description
Classic150
150
Classic 150
Classic200
200
Classic 200
Classic250
250
Classic 250
Classic250 KS
251
Classic 250 with 120 V Battery bank capability (lower current than 250)
Table 4120-1 Battery Stage (UPPER Byte of mbComboChrgStge register)
Name
Value
Description
Resting
0
Off , No Power, Waiting for Power Source, Battery V over set point, etc.
Absorb
3
Regulating battery voltage at Equalize Set point
BulkMppt
4
Max Power Point Tracking until Absorb (Bulk Terminate) Voltage reached
Float
5
Battery is FULL and regulating battery voltage at Float Set point
FloatMppt
6
Max Power Point Tracking. Seeking Float set point Voltage
Equalize
7
Regulating battery voltage at Equalize Set point
HyperVoc
10
Input Voltage is above maximum Classic operating Voltage
EqMppt
18
Max Power Point Tracking. Seeking Equalize set point Voltage
Table 4120-2 Classic States (LOWER Byte of mbComboChrgStge register)
Name
Value
Description
Internal Resting state 0
0
Internal state 1 through 6
1,2,3,4,5, 6,7
Internal state machine states