Owner`s manual

90 | P a g e
Table 4130-1 Info Flag Bits: READ ONLY
Flag
Value
Description
Classic Over Temperature
0x00000001
Classic Over Temperature if set
EEPROM error
0x00000002
Classic EEprom read/write found an error if set
RESERVED
0x00000004
RESERVED
Equalize In Progress
0x00000008
Equalize Charge stage Active if set
RESERVED
0x00000010
RESERVED
RESERVED
0x00000020
RESERVED
RESERVED
0x00000040
RESERVED
EQ MPPT
0x00000080
Battery V is less than EQ Voltage (EQ MPPT)
In V is Lower Than Out
0x00000100
Input Voltage (PV) is lower than Vbatt if set
Current Limit
0x00000200
User current limit or internal temperature current limt reached
HyperVoc
0x00000400
Hyper Voc PV input is between Vmax and Vmax+Vbatt
RESERVED
0x00000800
RESERVED
RESERVED
0x00001000
RESERVED
Battery Temp Sensor Installed
0x00002000
Battery temperature sensor installed if set
Aux1 State On
0x00004000
Aux 1 ON (aux 1 connector has V or relay closed)
Aux2 State On
0x00008000
Aux 2 ON (aux 2 connector has V present)
GroundFaultF
0x00010000
Ground Fault detected if set
DefCon4ErrF
0x00020000
FET Drive Error if set (lower priority than DefCon3)
ArcFaultF
0x00040000
Arc Fault occurred if set
NegBatCurrentF
0x00080000
Negative battery current if set
DefCon3ErrF
0x00100000
FET error (higher priority and DefCon 4)
XtraInfo2DsplayF
0x00200000
Extra info is available to display (Shading, etc)
PvPartialShadeF
0x00400000
Partial Shade detected during SOLAR sweep
WatchdogResetF
0x00800000
watchdog reset flag indicator (for debugging)
LowBatteryVF
0x01000000
VERY low battery) Vbatt is lower than 8.0 Volts
StackumperF
0x02000000
Stack Jumper is NOT installed if set
EqDoneF
0x04000000
EQ Finished. Resets when mode changed or new day
TempCompShortedF
0x08000000
Indication of shorted Temp Comp if set (all fans should
come on if this is true)
LockJumperF
0x10000000
Lock Jumper is NOT installed if set
XtraJumperF
0x20000000
Extra Jumper is NOT installed if set