Installation Manual Induction ranges

9
/ Installation requirements / Electrical connection
ELECTRICAL
A properly-grounded horizontally- mounted electri-
cal receptacle should be installed no higher than
3” (7.6 cm) above the fl oor, no less than 2” (5 cm)
and no more than 8” (20,3 cm) from the left side
(facing product).
Check all local code requirements.
.
Warning!
ELECTRICAL SHOCK HAZARD
Disconnect electrical power at the circuit bre-
aker box or fuse box before installing the ap-
pliance.
Provide appropriate ground for the appliance.
Use copper conductors only.
Failure to follow these instructions could re-
sult in serious injury or death.
Electrical grounding
This appliance is equipped with a three-prong
plug for your protection against shock hazard and
should be plugged directly into a properly groun-
ded socket. Do not cut or remove the grounding
prong from this plug.
Caution
Label all wires prior to disconnecting when
servicing controls. Wiring errors can cause
improper and dangerous operation.
Verify proper operation after servicing.
The appliance shall be connected to a single pha-
se electric line rated at 120/208Vac or 120/240Vac
and 60Hz frequency.
Install a suitable electric power supply receptacle
connection type NEMA 14-50R able to support a
load of at least 30 A (per line) according to local
code requirements. For four or three wires power
supply connection system see diagram below.
INSTALLATION REQUIREMENTS ELECTRICAL CONNECTION
installation area for the connection
Type Voltage Circuit rating Electrical
supply
30” IND-
DFM
120/208V
120/240V
10300W 46A
11000W 48A
40A
40A
30” IND-
DFS
120/208V
120/240V
11700W 53A
13000W 56A
40A
40A
36” IND-
DFM
120/208V
120/240V
14000W 62A
14800W 64A
40A
40A
36” IND-
DFS
120/208V
120/240V
15600W 70,5A
17000W 73,5A
50A
50A