Installation, Use and Care Manual
13
EXHAUSTHOODINSTALLATION
ThisrangewillbestperformwhenusedwithPRO
lineBertazzoniexhaustho ods. Thesehoods have
been designed to work in conjunction with the
Bertazzoni range and have the same finish for a
perfectlook.
For maximum performance, the height of the
bottomof thehoodfromthe worktopshould be
between 25 1/2" (65 cm) and 31 1/2" (80 cm).
This would typically result in the bottom of the
hoodbeing 611/2" (156.2cm)to67 1/2"(171.5
cm) above the floor. These measurements
provide for safe and efficient operation of the
hood.
Before installation of the exhaust hood,
consult
local or regional building and installation codes
foradditionalspecificclearancerequirements.
Refer to the range hood installation instructions
provided by the manufacturer for additional
information.
ELECTRICALCONNECTION
This unit is manufactured for a polarized,
grounded120volt/60Hz,16ampsystem.
Electricpowerconsumption is about1200W.
The minimum of 102 VAC is required for proper
operationofgasignitionsystems.
The circuit must be grounded and properly
polarized.
The unit is equipped witth a SJT power
cord. In
case of replacement, the power cord shall be
replaced with one of the same type, size and
length.
ELECTRICALGROUNDING
Thisapplianceisequippedwithathree‐prong
plugforyourprotectionagainstshockhazardand
shouldbepluggeddirectlyintoaproperly
groundedsocket.Donotcut
orremovethe
groundingprongfromthisplug.