Installation, Use and Care Manual

13
EXHAUSTHOODINSTALLATION
ThisrangewillbestperformwhenusedwithPRO
lineBertazzoniexhaustho ods. Thesehoods have
been designed to work in conjunction with the
Bertazzoni range and have the same finish for a
perfectlook.
For maximum performance, the height of the
bottomof thehoodfromthe worktopshould be
between 25 1/2" (65 cm) and 31 1/2" (80 cm).
This would typically result in the bottom of the
hoodbeing 611/2" (156.2cm)to67 1/2"(171.5
cm) above the floor. These measurements
provide for safe and efficient operation of the
hood.
Before installation of the exhaust hood,
consult
local or regional building and installation codes
foradditionalspecificclearancerequirements.
Refer to the range hood installation instructions
provided by the manufacturer for additional
information.
ELECTRICALCONNECTION
This unit is manufactured for a polarized,
grounded120volt/60Hz,16ampsystem.
Electricpowerconsumption is about1200W.
The minimum of 102 VAC is required for proper
operationofgasignitionsystems.
The circuit must be grounded and properly
polarized.
The unit is equipped witth a SJT power
cord. In
case of replacement, the power cord shall be
replaced with one of the same type, size and
length.
ELECTRICALGROUNDING
Thisapplianceisequippedwithathreeprong
plugforyourprotectionagainstshockhazardand
shouldbepluggeddirectlyintoaproperly
groundedsocket.Donotcut
orremovethe
groundingprongfromthisplug.