Installation, Use and Care Manual
22
STEP6:MINIMUMFLAMEADJUSTMENT
WARNING!
Theseadjustmentsshouldbemadeonlyforuse
oftheappliancewithnaturalgas.Forusewith
liquidpropanegas,thechokescrewmustbe
fullyturnedinaclockwisedirection.
SURFACEBURNERS
1. Light one burner at a time and set the
knob
totheMINIMUMposition(smallflame).
2. Removetheknob.
3. The range is equipped with a safety valve.
Using asmall‐sizeslotted screwdriver, locate
the choke valve on the valve body and turn
the choke screwto the right orleft until the
burnerflameisadjustedto
desiredminimum.
4. Make sure that the flame does not go out
when switching quickly from the MAXIMUM
totheMINIMUMposition.
OVENBURNER
1. Settheoventemperaturecontrolknobtothe
MAXIMUMsetting.
2. Closetheovendoorandoperatetheovenfor
atleast10minutes.
3. Set the knob to the MINIMUM setting
(corresponding to 275°F/135°C or
220°F/105°C).
4. Removetheknob.
5. With a slotted screwdriver turn
the choking
screw(by‐pass screw at the left side of the
thermostat bar) and, while observing the
flame at the same time through the bottom
oven porthole, evaluate the consistency of
the flame so it remains on when switching
quickly from MINIMUM to MAXIMUM
setting.
Broiler burner: the broiler burner always
operates at maximum, therefore no minimum
adjustmentisrequired.
Burner Position Injector Gas Pressure Max Rate Min Rate By-pass
diam. [mm.] Type [i.w.c.] [BTU/h] [W] [BTU/h] [W] diam. [mm]
Auxiliary Front R
0,92 NG 4" 3750 1098 900 264
Regulated
0,56 LP(Propane) 11” 3750 1098 900 264
0,29
Semi-Rapid Rear L & C
1,17 NG 4” 6000 1759 1500 439
Regulated
Front C
0,73 LP(Propane) 11” 6300 1845 1500 439
0,36
Rapid Rear R
1,55 NG 4” 10400 3046 2500 732
Regulated
0,98 LP(Propane) 11” 11400 3339 2500 732
0,47
Front L Inner
0,80 NG 4” 2730 799 900 264
Regulated
Dual Burner
0,50 LP(Propane) 11” 2900 849 900 264
0,29
Front L Outer
N°2x1,30 NG 4” 15000 4394 4500 1318
Regulated
N°2x0,83 LP(Propane) 11” 16400 4804 4500 1318
0,65
Oven Oven Left 1,85 NG 4” 14500 4248 3500 1025 Regulated
(left cavity) downside 1,10 LP (Propane) 11” 14500 4248 3500 1025 0,54
Broiler Oven Left 1,70 NG 4” 12000 3516 Only Max Only Max No by-pass
(left cavity) upside 0,98 LP (Propane) 11” 12000 3516 Only Max Only Max No by-pass
Oven Oven Right 1,25 NG 4” 7000 2051 2400 703 Regulated