FOR ALL INSTALLATIONS REMOVE ALL WHITE PLASTIC PROTECTIVE COVERING FROM
HOOD, SIDE RAILS, TRIM, GREASE RAILS AND GREASE FILTERS.
RECIRCULATING INSTALLATIONS
IT IS HIGHLY RECOMMENDED THAT PROFESSIONAL STYLE COOKING ALWAYS BE VENTED
TO THE OUTSIDE. For recirculating installations (Figure 1), Charcoal Filters are necessary. Remove
all grease lters and set aside. Attach one charcoal lter to each end of the blower. Each charcoal lter
attaches to the grid on the side of the blower. Rotate the lter clockwise to install and counterclockwise
to remove (Figure 1A). Replace all grease lters. Recirculating installations also require some duct work
to divert the air out of the top or face or side of the cabinet or custom hood or out of the side / face of
the soft and back into the kitchen. Install at least 15" of vertical run of metal duct (Figure 1) at the air
outlet. Run the duct vertically and secure it at the relevant opening previously cut out at the top or side
of the cabinet or soft. A metal duct cover grille is also recommended. The duct work must not terminate
inside the cabinet or custom hood.