manual
4
TABLE N°1: Adaption to various types of gas    APPLIANCE CATEGORY: II2H3+ 
Brännare Gastyp Tryck Diameter 
munstycke
Nominell kapacitet  Reducerad 
kapacitet 
Diameter 
by-pass 
    mbar 1/100 mm  g/h  l/h  kW  kcal/h kW kcal/h 1/100 mm 
  Naturgas G20  20  77  -  95  1,00  860 0,48 413  34 jus.   
  Stads gas G110  8  145   -  227  1,00  860  0,48  413  34 jus.   
Extra  Stads gas G120  8  135   -  203  1,00  860  0,48  413  34 jus.   
  Butangas G30  28-30  50  73  -  1,00  860 0,48 413  34   
  Propangas G31  37  50  71  -  1,00  860 0,48 413  34   
 Naturgas G20 20 101 - 167 1,75 1505 0,6 516 36 jus.  
  Stads gas G110  8  192   -  397  1,75  1505  0,6  516  36 jus.   
Halvsnabb  Stads gas G120  8  180   -  355  1,75  1505  0,6  516  36 jus.   
 Butangas G30 28-30 66 127 - 1,75 1505 0,6 516 36  
 Propangas G31 37 66 125 - 1,75 1505 0,6 516 36  
 Naturgas G20 20 129 - 286 3,00 2580 1,05 903 52 jus.  
  Stads gas G110  8  280   -  681  3,00  2580  1,05  903  52 jus.   
Snabb  Stads gas G120  8  260   -  608  3,00  2580  1,05  903  52 jus.   
  Butangas G30  28-30  87  218  -  3,00  2580  1,05  903  52   
 Propangas G31 37 87 214 - 3,00 2580 1,05 903 52  
  Naturgas G20  20  70   -  76  0,80  688 0,48 413  34 jus.   
Dual  Stads gas G110  8  130   -  181  0,80  688  0,48  413  34 jus.   
Inre  Stads gas G120  8  130   -  162  0,80  688  0,48  413  34 jus.   
  Butangas G30  28-30  46  58  -  0,80  688 0,48 413  34   
  Propangas G31  37  46  57  -  0,80  688 0,48 413  34   
  Naturgas G20  20  2x110   - 419  4,40  3784 1,8 1548  65 jus.   
  Stads gas G110  8  2x300   -  419  4,40  3784  1,8  1548  65 jus.   
Dual  Stads gas G120  8  2x290   -  419  4,40  3784  1,8  1548  65 jus.   
Yttre  Butangas G30  28-30  2x69  298  -  4,10  3526 1,8 1548  65   
  Propangas G31  37  2x69  293  -  4,10  3526 1,8 1548  65   
  Naturgas G20  20  150   -  429  4,5  3870  2  1720  70 jus.   
Ugn 
Butangas G30  28-30  95 
327 - 4,5 3870 2 1720 70 
 Propangas G31 37 95 321 - 4,5 3870 2 1720 70  
BURNER ADJUSTMENT 
1)Primary air adjustment: 
Oven burner adjustment: follow the instructions below to adjust the primary air for the over burner: 
1) Remove the oven bottom. 
2) Loosen the screw P and adjust the position X of the Venturi cone (Fig. 15) according to the measurements indicated in 
table 2. 
TABLE N°2: Burner primary air regulation (indicative) 
BURNER 
Type of gas  Oven (mm) 
Natural G20  fully open 
Butane G30  fully open 
Propane G31  fully open 
2) Burner "MINIMUM" adjustment: 
Work surface burner adjustment: follow the instructions below to adjust the work surface burner minimum: 
1) Light the burner and set the knob to the MINIMUM position (small flame). 
2) Remove the knob of the valve that is press fit on the rod of that valve. 
3) If the cooker is not equipped with safety valves on the surface burners, insert a small slotted screwdriver into the hole 
on the valve rod (Fig. 16) and turn the choke screw to the right or left until the burner flame is adjusted to minimum. If the 
cooker is equipped with safety valves, the choke valve is not located in the rod hole, but on the valve body (see fig. 17). 
4) Make sure that the flame does not go out when switching quickly from the MAXIMUM to the MINIMUM position. 
Oven burner adjustment: follow the instructions below to adjust the minimum: 
1) Light the burner setting the knob to the MAXIMUM position. 
2) Close the oven door and operate the oven for at least 10 minutes. 
3) Set the knob to the MINIMUM position (corresponding to 120°) and then remove it. 
4) With a slotted screwdriver turn the choking screw (see figure 18) and, while observing the flame at the same time 
through the cooker porthole, evaluate the consistency of the flame so it remains on when switching quickly from the 
MINIMUM to the MAXIMUM position. 
WARNING: The above-mentioned adjustment should be made only with methane gas burners, while for those 
operating with liquid gas the screw must be locked at the end in a clockwise direction. The grill 
burner always operates at maximum and therefore no minimum adjustment is required. 
APPLIANCE ELECTRIC CONNECTION: 
The electric connection must comply with the current legal standards and regulations. 
Before making the connection, check that: 