Oven User Manual
4
TABLE N°1: Adaption to various types of gas    APPLIANCE CATEGORY: II2H3+ 
Burner Types of Gas Pressure  Nozzle 
Diameter 
Rater Capacity  Reduced 
Capacity 
by-pass 
Diameter 
    mbar  1/100 mm.  g/h  l/h  kw  kcal/h  kw  kcal/h  1/100 mm. 
  Natural G20  20  72  -  95  1  860  0,48  413  34 reg. 
Auxiliary  Butane G30  30  50  73  -  1  860  0,48  413  34 
 Propane G31 37 50 71 - 1 860 0,48 413 34 
  Natural G20  20  97  -  167  1,75  1505  0,6  516  36 reg. 
Semi-Rapid  Butane G30  30  65  127  -  1,75  1505  0,6  516  36 
 Propane G31 37 65 125 - 1,75 1505 0,6 516 36 
  Natural G20  20  115  -  286  3  2580  1,05  903  52 reg. 
Rapid  Butane G30  30  85  218  -  3  2580  1,05  903  52 
 Propane G31 37 85 214 - 3 2580 1,05 903 52 
Dual  Natural G20  20  72  -  95  1  860  0,48  413  34 reg. 
Inner  Butane G30  30  46  73  -  1  860  0,48  413  34 
 Propane G31 37 46 71 - 1 860 0,48 413 34 
Dual  Natural G20  20  102  -  334  3,5  3010  1,8  1548  65 reg. 
Outer  Butane G30  30  66  254  -  3,5  3010  1,8  1548  65 
  Propane G31 37  66  250  - 3,5 3010 1,8 1548 65 
  Natural G20  20  125  -  286  3  2580  1  860  48 reg. 
Oven  Butane G30  30  85  218  -  3  2580  1  860  48 
 Propane G31 37 85 214 - 3 2580 1 860 48 
BURNER ADJUSTMENT 
1)Primary air adjustment: 
Oven burner adjustment: follow the instructions below to adjust the primary air for the over burner: 
1) Remove the oven bottom. 
2) Loosen the screw P and adjust the position X of the Venturi cone (Fig. 15) according to the measurements indicated in 
table 2. 
TABLE N°2: Burner primary air regulation (indicative) 
BURNER 
Type of gas  Oven (mm) 
Natural G20  fully open 
Butane G30  fully open 
Propane G31  fully open 
2) Burner "MINIMUM" adjustment: 
Work surface burner adjustment: follow the instructions below to adjust the work surface burner minimum: 
1) Light the burner and set the knob to the MINIMUM position (small flame). 
2) Remove the knob of the valve that is press fit on the rod of that valve. 
3) If the cooker is not equipped with safety valves on the surface burners, insert a small slotted screwdriver into the hole 
on the valve rod (Fig. 16) and turn the choke screw to the right or left until the burner flame is adjusted to minimum. If the 
cooker is equipped with safety valves, the choke valve is not located in the rod hole, but on the valve body (see fig. 17). 
4) Make sure that the flame does not go out when switching quickly from the MAXIMUM to the MINIMUM position. 
Oven burner adjustment: follow the instructions below to adjust the minimum: 
1) Light the burner setting the knob to the MAXIMUM position. 
2) Close the oven door and operate the oven for at least 10 minutes. 
3) Set the knob to the MINIMUM position (corresponding to 120°) and then remove it. 
4) With a slotted screwdriver turn the choking screw (see figure 18) and, while observing the flame at the same time 
through the cooker porthole, evaluate the consistency of the flame so it remains on when switching quickly from the 
MINIMUM to the MAXIMUM position. 
WARNING: The above-mentioned adjustment should be made only with methane gas burners, while for those 
operating with liquid gas the screw must be locked at the end in a clockwise direction. The grill 
burner always operates at maximum and therefore no minimum adjustment is required. 
APPLIANCE ELECTRIC CONNECTION: 
The electric connection must comply with the current legal standards and regulations. 
Before making the connection, check that: 
- The system electrical rating and the current outlets are adequate for the maximum power output of the appliance (see 
the label applied to the bottom of the casing). 
- The outlet or the system is equipped with an efficient ground connection in accordance with the current legal standards 
and regulations. The company will not be responsible for the non-compliance with these instructions. 
When the connection to the power supply network is made using an outlet: 
- If the power cord is supplied without a plug, apply a standard plug that is suitable for the load indicated on the label. 
Connect the wires according to the diagram shown in FIG.19 and check that: 
letter L (phase) = brown wire; 
letter N (neutral) = blue wire; 
ground symbol
 = green-yellow wire; 