Installation, Use and Care Manual

15
PRESSUREREGULATOR
Since service pressure may fluctuate with local
demand, every gas cooking appliance must be
equipped with a pressure regulator on the
incoming service line for safe and efficient
operation.
The pressure regulator shipped with the
appliance has two female threads ½” NPT. The
regulatorshallbeinstalledproperly in
ordertobe
accessible when the appliance is installed in its
finalposition.
Manifoldpressureshouldbecheckedwitha
manometerandcomplywiththevaluesindicated
below:
Naturalgas4.0"W.c.P.
LP/Propane11.0"W.C.P.
Incominglinepressureupstreamfromthe
regulatormustbe1"W.c.P.higherthan
the
manifoldpressureinordertocheckthe
regulator.
Theregulatorusedonthisrangecanwithstanda
maximuminputpressureof1/2PSI(13.8"w.c.or
3,5kPa)Ifthelinepressureexceedsthatamount,
astepdownregulatorisrequired.
The appliance, its individual shutoff valve, and
the pressure regulator must be disconnected
from the gas line during any pressure testing of
that system at pressures in excess of 1/2 PSI
(13,8”w.c.or3.5kPa).
The individual manual shutoff valve must be in
the OFF position during any pressure testing of
the gas supply piping system
at test pressures
equal to or less than 1/2 PSI (13,8” w.c. or 3.5
kPa).
APPLIANCESERVING
Beforecarryinganyservicingoperation
disconnecttheappliance fromgasandelectric
supplyandextraappliancefromfinalinstallation
placeinordertohaveaccesstotheappliancefor
properservicingintervention.
GASCONVERSION
WARNING!
Beforecarryingoutthisoperation,disconnect
theappliancefromgasandelectricity.
Gasconversionshallbeconductedbyafactory
trainedprofessional.
Callthecustomerservicehotlinetoidentifya
factorytrainedprofessionalnearyourhome.
The gas conversion procedure for this range
includes6steps:
1. Pressureregulator
2.
Surfaceburners
3. Adjustmentofminimumsetting
The conversion is not completed if all 6 steps
havenotbeenconcludedproperly.
Beforeperformingthegasconversion,locatethe
package containing the replacement nozzle
shipped with every range. IMPORTANT: Each
nozzle has a number indicating itsflow diameter
printedonthe
body.Consultthetableonpage20
formatchingnozzlestoburners.
Savethenozzlesremovedfromtherangefor
futureuse.