Installation, Use and Care Manual

6
BEFOREINSTALLATION
This appliance shall only be installed by an
authorizedprofessional.
This appliance shall be installed in accordance
withthemanufacturer’sinstallationinstructions.
This appliance must be installed in accordan ce
withthenorms&standar ds ofthecou ntry where
it will be installed. The installation of this
appliance must conform to local
codes and
ordinances. In the absence of local codes,
InstallationsmustconformstoAmericanNational
Standards,NationalFuelGasCodeANSIZ223.1
latestedition/NFPA54orB149.1.
The appliance, when installed, must be
electrically grounded in accordance with local
codes or, in the absence of local codes, with the
NationalElectricalCode,ANSI/NFPA70.
If local codes permit, a flexible metal appliance
connection with the new AGA or CGA certified
design, max. 5 feet (1,5 m) long, ½” I.D. is
recommended for connecting this appliance to
the gas supply line. Do not bend or damage the
flexibleconnectorwhenmoving
theappliance.
This appliance must be used with the pressure
regulator provided. The regulator shall be
properlyinstalled in order to be accessible when
theapplianceis installed in its final location. The
pressureregulatormustbesetforthetypeofgas
tobeused.Thepressureregulatorhas
½”female
pipe thread. The appropriate fitting must be
determined basedon the size of your gas supply
line,theflexiblemetalconnectorandtheshutoff
valve.
The appliance must be isolated from the gas
supply piping system by closing its individual
manualshutoffvalveduringanypressuretesting
ofthe
gassupplypipingsystemattestpressures
equal to or less than 1/2 PSI (13,8” w.c. or 3,5
kPa).
All opening andholes in the wall and floor, back
and under the appliance shall be sealed before
installationoftheappliance.
Amanualvalveshall beinstalledinanaccessible
location in the gas line external to the appliance
for the purpose of turning on or shutting off gas
totheappliance
totheappliance
WARNING: This appliance shall not be installed
with a ventilation system that air downward
towardthe ra nge/rangetop/cooktop;thistypeof
ventilation system may cause ignition and
combustion problem with the gas cooking
appliance resulting in a personal injury or
unintendedoperation.
WARNING: an air curtain or other overhead
range/rangetop/cooktop hood, which operates
by blowing a downward airflow onto a
range/rangetop/cooktop, shall not be
used/installed in conjunction with this gas
range/rangetop/cooktop.
WARNING!
Donotuseaerosol
spraysinthevicinityofthis
appliancewhileitisinoperation
ROOM VENTILATION: An exhaust fan may be
used with the appliance; in each case it shall be
installed in conformity with the appropriate
national and local standards. Exhaust hood
operationmay affect other vented appliances;in
each case it
shall be installed in conformity with
theappropriatenationalandlocalstandards.
TYPEOFGAS
Thisapplianceisshippedfromthefactoryforuse
with natural gas. For use with propane LP gas
please follow the conversion procedure
described on pg. 17. A step by step conversion
procedureisalso
includedwitheachsetofLPgas
nozzles.
GASPRESSURE
Themaximuminletgassupplypressureincoming
tothegasappliancepressureregulatoris1/2PSI
(13,8’’w.c.or3,5kPa).
The minimum gas supply pressure for checking
theregulatorsettingshallbeatleast1“w.c.(249
Pa)above
theinletspecifiedmanifoldpressureto
the appliance (this operating pressure is 4” w.c.
(1.00kPa)forNaturalGasand 11”w.c.(2.75 kPa
forLPGas).