Range User Manual

13
ELECTRICALCONNECTION
The appliance shall be connected toa single
phase electric line rated at 120/208Vac or
120/240Vacand60Hzfrequency.
Electricpowerrating:
‐120/208Vac:2400Wattor12.0Amax.
‐120/240Vac:3100Wattor13.5Amax.
Heatingelementspowerrating:
‐Ovenbakeelement=1800Watt
‐Ovencircular
element=3000Watt
‐Ovendoublebroilelement=1200+1800Watt
Installa suitableelectricpowersupplyreceptacle
connection type NEMA 1450R able to support a
load of at least 16 A (per line)according to local
coderequirements.Forfourorthreewirespower
supplyconnectionsystemsee
diagrambelow.
FOUR-WIRE CONN.RECEPTACLE NEMA 14-50R
THREE-WIRE CONN.RECEPTACLE NEMA 14-50R
Check your local code for which of the options
belowshould be usedin grounding the
receptaclepowersupplyconnections.
OPTION 1 – FOUR Wires connection:
‐ Connect the L1 receptacle terminal to the
incoming BLACK electrical supply wire (L1hot
wire)
‐ Connect the L2 receptacle terminal to the
incoming RED electrical supply wire (L2hot
wire)
‐ Connect the NEUTRAL receptacle terminal to
the incoming NEUTRAL (WHITE) electrical
supplywire
‐ Connect the GROUND receptacle terminal to
the incoming GROUND (GREEN) electrical
supplywire
OPTION 2 - THREE-Wires connection:
‐ Connect the L1 receptacle terminal to the
incoming BLACK electrical supply wire (L1hot
wire)
‐ Connect the L2 receptacle terminal to the
incoming RED electrical supply wire (L2hot
wire)
‐ Connect the NEUTRAL with the GROUND
receptacle terminal to the incoming NEUTRAL
(WHITE)electricalsupplywire
DO NOT USE EXTENSION CORDS WITH THIS
APPLIANCE AS IT MAY RESULT IN FIRE,
ELECTRIC SHOCK OR OTHER type of
PERSONAL INJURY.
The appliance isequipped at the fa ctory with an
electric supply cord set 4 wires type with ring
terminals (L1, L2, N, Ground) suitable for range
use UL/CSA listed type SRDT/DRT 2x6AWG (L1,
L2)+2x8AWG (N, G) rated 300V, 40 or 50A with
fused plug type NEMA 1450P; cable length 1,5
m.;incasethesupplycordsetmustbereplaced,
it shall be replaced with anidentical set having
the same technical specs and followingcarefully
theinstructionsanddiagramsbelow:
1) Disconnect appliance from electrical power
supplyreceptacle
2) Slideouttheappliancefrominstallationplace
toaccessto
backenclosurepanel
3) Remove back enclosure panel by removing
the6screwsasshownbelow