Operation Manual
Yellow/Green wire: connect to GND (ground)
A dedicated line and junction box should be used to connect the oven to a 20 A circuit.
ROOM VENTILATION – LOCATION AND VENTING.
ATTENTION: An exhaust fan may be used with the appliance; in each case it shall be installed in
conformity with the national standards in force.
ATTENTION: Exhaust hood operation may affect other vented appliances; in each case it shall be
installed in conformity with the national standards in force.
- CHANGING THE NOZZLES FOR USE WITH OTHER TYPES OF GAS:
To change the nozzles of the burners use the following procedure:
Lift up the burners and unscrew the nozzles ( Fig. 9) using an adjustable spanner of 7 mm and change the
nozzles with those designed for the new gas supply according to the information given in TABLE A shown
below.
TABLE A: Adapting to different types of gas
Burner
Inj. size
Gas
Pressure
Max Rate
Min Rate
By-pass size
1/100mm
Type
[mbar]
g/h
l/h
kw
kcal/h
kw
kcal/h
1/100mm
192
Town G110
8
-
397
1,75
1505
0,44
378
31 reg.
Semi-Rapid
101
Natural G20
20
-
167
1,75
1505
0,44
378
31 reg.
66
Butane G30
30
127
-
1,75
1505
0,44
378
31
66
Propane G31
37
125
-
1,75
1505
0,44
378
31
280
Town G110
8
-
681
3
2580
0,75
645
42 reg.
Rapid
129
Natural G20
20
-
286
3
2580
0,75
645
42 reg.
87
Butane G30
30
218
-
3
2580
0,75
645
42
87
Propane G31
37
214
-
3
2580
0,75
645
42
130
Town G110
8
-
181
0,8
688
0,3
258
27 reg.
Inner
70
Natural G20
20
-
76
0,8
688
0,3
258
27 reg.
46
Butane G30
30
58
-
0,8
688
0,3
258
27
Dual
46
Propane G31
37
57
-
0,8
688
0,3
258
27
N°2 x 300
Town G110
8
885
3,9
3354
1,8
1549
65 reg
burner
Outer
N°2 x 110
Natural G20
20
-
419
4.4
3784
1,8
1548
65 reg
N°2 x 69
Butane G30
30
298
-
4,1
3526
1,8
1548
65
N°2 x 69
Propane G31
37
293
-
4,1
3526
1,8
1548
65
CAUTION: save the orifices removed from the appliance for future use
Regulation of burners
Regulation of the "MINIMUM" on the burners
To regulate the minimum on the burners carry out the following procedure indicated below:
1) Turn on the burner and put the knob onto position MINIMUM ( small flame ).
2) Remove the knob ( Fig. 11) of the tap which is set for standard pressure. The knob is found on the bar of
the tap itself.
3) Beside the tap bar on the work top, use a small screwdriver that fits the screw (gold) found on the lower
part of the tap and turn the fixing screw to the right or left until the flame of the burner is regulated in the most
suitable way to MINIMUM.
4) Make sure that that the flame does not go out when changing the position quickly from MAXIMUM to the
MINIMUM position.
ATTENTION: The regulation described above can be carried out only with burners using natural gas,
while with burners using propane gas the screw must be fully screwed in, in a clockwise direction.
DESCRIPTION
DESCRIPTIVE CAPTION FOR HOB (fig.9)
1. Dual burner
2 Rapid burner
3. Rear Induction element
4. Front induction element