To change the nozzles of the burners use the following procedure:
Lift up the burners and unscrew the nozzles ( Fig. 9) using an adjustable spanner of 7 mm and change the
nozzles with those designed for the new gas supply according to the information given in TABLE A shown
below.
TABLE N°2: Adapting to different types of gas APPLIANCE CATEGORY: II2H3+
Burner Type of Gas Pressure Nozzle Nominal Charge Reduced Charge Diameter
diameter by-pass 1/100mm
mbar 1/100mm g/h l/h Kw kcal/h kw kcal/h
Town G110 8 192 - 397 1,75 1505 0,44 378 31 reg
Semi- Natural G20 20 101 - 167 1,75 1505 0,44 378 31 reg
Rapid Butane G30 28 66 127 - 1,75 1505 0,44 378 31
Propane G31 37 66 125 - 1,75 1505 0,44 378 31
Town G110 8 280 - 681 3 2580 0,75 645 42 reg
Natural G20 20 129 - 286 3 2580 0,75 645 42 reg
Rapid Butane G30 28 87 218 - 3 2580 0,75 645 42
Propane G31 37 87 214 - 3 2580 0,75 645 42
Town G110 8 130 - 181 0,8 688 0,30 258 27 reg
Dual Natural G20 20 70 - 76 0,8 688 0,30 258 27 reg
burner Butane G30 28 46 211 - 0,8 688 0,30 258 27
inner Propane G31 37 46 207 - 0,8 688 0,30 258 27
Town G110 8 2x300 - 885 4,4 3784 1,8 1548 65 reg
Dual Natural G20 20 2x110 - 419 4,4 3784 1,8 1548 65 reg
burner Butane G30 28 2x69 298 - 4,1 3526 1,8 1548 65
outer Propane G31 37 2x69 293 - 4,1 3526 1,8 1548 65
CAUTION: save the orifices removed from the appliance for future use
Regulation of burners
Regulation of the "MINIMUM" on the burners
To regulate the minimum on the burners carry out the following procedure indicated below:
1) Turn on the burner and put the knob onto position MINIMUM ( small flame ).
2) Remove the knob ( Fig. 10) of the tap which is set for standard pressure. The knob is found on the bar of
the tap itself.
3) Beside the tap bar on the work top, use a small screwdriver that fits the screw (gold) found on the lower
part of the tap and turn the fixing screw to the right or left until the flame of the burner is regulated in the most
suitable way to MINIMUM.
4) Make sure that that the flame does not go out when changing the position quickly from MAXIMUM to the
MINIMUM position.
ATTENTION: The regulation described above can be carried out only with burners using natural gas,
while with burners using propane gas the screw must be fully screwed in, in a clockwise direction.
Descriptions
DESCRIPTIVE CAPTION FOR HOB (fig.11)
1. Dual burner
2 Griddle
3. Rapid burner
4. Medium burner
5. Dual out burner control knob
6. Dual in burner control knob
7. Rear element griddle control knob
8. Front element griddle control knob
9. Rapid burner control knob
10. Medium burner control knob