Operation Manual
ATTENTION: The appliance conforms with the regulations of directives 90/396EEC (Gas Directive)
regarding gas appliances for domestic use and the like, 93/68 and 73/23 (Low Voltage Directive) regarding
electrical safety and 2004/108/CE, 93/68 and 89/336 (EMC Directive) regarding electromagnetic
compatibility.
Room ventilation – Location and venting.
ATTENTION: An exhaust fan may be used with the appliance; in each case it shall be installed in
conformity with the national standards in force.
ATTENTION: Exhaust hood operation may affect other vented appliances; in each case it shall be
installed in conformity with the national standards in force.
- CHANGING THE NOZZLES FOR USE WITH OTHER TYPES OF GAS:
To change the nozzles of the burners use the following procedure:
Lift up the burners and unscrew the nozzles ( Fig. 9) using an adjustable spanner of 7 mm and change the
nozzles with those designed for the new gas supply according to the information given in TABLE A shown
below.
TABLE N°2: Adapting to different types of gas APPLIANCE CATEGORY: II2H3+
Burner
Type of Gas
Pressure
Nozzle
Nominal Charge
Reduced Charge
Diameter
diameter
by-pass 1/100mm
mbar
1/100mm
g/h
l/h
Kw
kcal/h
kw
kcal/h
Semi-
Natural G20
20
101
-
167
1,75
1505
0,44
378
31 reg
Rapid
Butane G30
28
66
127
-
1,75
1505
0,44
378
31
Propane G31
37
66
125
-
1,75
1505
0,44
378
31
Natural G20
20
129
-
286
3
2580
0,75
645
42 reg
Rapid
Butane G30
28
87
218
-
3
2580
0,75
645
42
Propane G31
37
87
214
-
3
2580
0,75
645
42
Dual
Natural G20
20
70
-
76
0,8
688
0,30
258
27 reg
burner
Butane G30
28
46
211
-
0,8
688
0,30
258
27
inner
Propane G31
37
46
207
-
0,8
688
0,30
258
27
Dual
Natural G20
20
2x110
-
419
4,4
3784
1.8
1548
65 reg
burner
Butane G30
28
2x69
298
-
4,1
3526
1.8
1548
65
outer
Propane G31
37
2x69
293
-
4,1
3526
1.8
1548
65
CAUTION: save the orifices removed from the appliance for future use
Regulation of burners
Regulation of the "MINIMUM" on the burners
To regulate the minimum on the burners carry out the following procedure indicated below:
1) Turn on the burner and put the knob onto position MINIMUM ( small flame ).
2) Remove the knob ( Fig. 10) of the tap which is set for standard pressure. The knob is found on the bar of
the tap itself.
3) Beside the tap bar on the work top, use a small screwdriver that fits the screw (gold) found on the lower
part of the tap and turn the fixing screw to the right or left until the flame of the burner is regulated in the most
suitable way to MINIMUM.
4) Make sure that that the flame does not go out when changing the position quickly from MAXIMUM to the
MINIMUM position.
ATTENTION: The regulation described above can be carried out only with burners using natural gas,
while with burners using propane gas the screw must be fully screwed in, in a clockwise direction.
Descriptions
DESCRIPTIVE CAPTION FOR HOB (fig.11)
1. Dual burner
2 Griddle
3. Rapid burner
4. Medium burner
5. Dual out burner control knob
6. Dual in burner control knob
7. Rear element griddle control knob
8. Front element griddle control knob