Specifications
12
INSTALLINGTHEANTI‐TIPStabilityDEVICE
Theanti‐tipbracketshippedwiththerangemust
beproperly secured to therear wallasshown in
thepicturebelow.
Theheightofthebracketfromthefloormustbe
determined after the range legs have been
adjusted to the desired height and
afterthe
rangehasbeenlevelled.
Measure the distance from the floor to the
bottom of the anti‐tip bracket receptac le on the
backoftheappliance.
Position the two anti‐tip brackets on the wall at
the desired height plus 1/8" (0.32 cm). The
bracketsmustbe placedat
2”5/16(6,0cm)from
the side of the range. The distance between the
twobracketis31”1/4(79.3cm).
Secure the brackets to the wall with appropriate
hardware.
Slidetherangeagainstthewalluntilthebrackets
are fully inserted into their receptacles on the
backoftherange.
INSTALLATIONREQUIREMENTS
ELECTRICAL
A properly grounded and horizontally‐mounted
electrical receptacle Type NEMA 14‐50R should
beinstallednohigherthan3"(7.6cm)abovethe
floor,nolessthan2”(5cm)andnomorethan8”
(20,3 cm) from the left side (facing product);
refer to ELECTRICAL CONNECTION section pag.
13.
Checkalllocalcoderequirements.
GAS
Anagency‐approved,properly‐sizedmanualshut‐
off valve should be installed no higher than 3"
(7.6 cm) above the floor and no less than 2” (5
cm)andnomorethan8”(20.3cm)fromtheright
side(facingproduct).
To connect gas
between shut‐off valve and
regulator, use agency‐approved, properly sized
flexible or rigid pipe. Check all local code
requirements.