Electrical connection 
The connection of the hobs to mains is effected via the flex and the three pin plug located underneath the 
hotplate. The appliance operate at a main voltage of 120V a.c., frequency 60Hz. Electric power absorption is 
about 1W for 5 gas burner version or 2W for 6 gas burners version. 
WARNING: Electrical Grounding Instructions: This appliance is equipped with a (three-prong) 
grounding plug for your protection against shock hazard and should be plugged directly into a 
properly grounded receptable. Do not cut or remove the grounding prong from this plug. 
Wiring diagrams   Wiring diagram description  
see Fig. 12.   1. Cable terminal 
 2. Ignition switch 
3. Spark generator 
4. Ignition spark 
L. Black 
N. White 
T. Green (earth) 
Room ventilation – Location and venting. 
ATTENTION: An exhaust fan may be used with the appliance; in each case it shall be installed in 
conformity with the national standards in force. 
ATTENTION: Exhaust hood operation may affect other vented appliances; in each case it shall be 
installed in conformity with the national standards in force. 
Conversion to different types of gas 
Before carrying out any maintenance work, disconnect the appliance from the gas and electric 
supply. For Natural Gas fit regulator assembly described in Fig. 5. For LP Gas fit assembly described 
in fig. 5. 
 - CHANGING THE NOZZLES FOR USE WITH OTHER TYPES OF GAS: 
To change the nozzles of the burners use the following procedure:  
Lift up the burners and unscrew the nozzles ( Fig. 8) using an adjustable spanner of 7 mm and change the 
nozzles with those designed for the new gas supply according to the information given in TABLE A shown 
below. 
TABLE A: Adapting to different types of gas 
Burner  Position Inj. size  Gas  Pressure  Max Rate  Min Rate  By-pass size
 1/100mm Type [i.w.c.] [BTU/h] [W] [BTU/h] [W] [1/100mm] 
Auxiliary  Front R  92  NG  4”  3750  1098  900  264  Regulated 
  56 LP(Propane) 11” 3750 1098 900 264 29 
Semi-Rapid  Rear L  117  NG  4”  6000  1759  1500  439  Regulated 
  73 LP(Propane) 11” 6300 1845 1500 439 36 
Rapid  Rear R  155  NG  4”  10400  2046  2500  732  Regulated 
  98 LP(Propane) 11” 11400 3339 2500 732 47 
  Front L Inner  80  NG  4”     
900 264 
Regulated 
Dual    50  LP(Propane) 11”  NG 17000  4980  29 
burner  Front L Outer  N°2 x 130  NG  4”  LP 18800  5507  Regulated 
    N°2 x 83  LP(Propane) 11”      65 
CAUTION: save the orifices removed from the appliance for future use 
Regulation of burners 
Regulation of the "MINIMUM" on the burners 
To regulate the minimum on the burners carry out the following procedure indicated below: 
1) Turn on the burner and put the knob onto position MINIMUM ( small flame ). 
2) Remove the knob ( Fig. 9) of the tap which is set for standard pressure. The knob is found on the bar of 
the tap itself. 
3) Beside the tap bar on the work top, use a small screwdriver that fits the screw (gold) found on the lower 
part of the tap (auxiliary, semirapid, rapid Fig. 9) (dual fig.10) and turn the fixing screw to the right or left until 
the flame of the burner is regulated in the most suitable way to MINIMUM. 
4) Make sure that that the flame does not go out when changing the position quickly from MAXIMUM to the 
MINIMUM position. 
ATTENTION: The regulation described above can be carried out only with burners using natural gas, 