Installation, Use and Care Manual
6
Adaptation of the pressure regulator for use with different type of gas 
The pressure regulator supplied with the appliance is a convertible type pressure regulator for use with 
Natural Gas at a nominal outlet pressure of 4” w.c. or LP gas at a nominal outlet pressure of 11” w.c. and it is 
pre-arranged from the factory to operate with one of these gas/pressure as indicated in the pre-arranging 
labels affixed on the appliance, package and Instruction booklet. 
To convert the regulator for use with the other gas different from which one it is pre-arranged it is enough 
perform the following operations: 
1) Unscrew by hand the upper metal stopper of the regulator (Fig. 5). 
2) Unscrew by hand the white plastic piece screwed under the above mentioned metal stopper, afterward 
screw it again in opposite way under the metal stopper (for gas reference see the written “LP” and “NAT” with 
relative indicating arrows on the white piece). 
3) Screw again by hand the metal stopper in the original position on the regulator. 
Operating in this way the gas regulator is converted for use with the other gas/pressure. 
Descriptions 
DESCRIPTIVE CAPTION FOR HOB (Fig. 11)  
1. Small Burner         
2. Medium burner         
3. Rapid burner   
4. Dual burner   
5. Front right side burner control knob 
6. Front left side burner control knob  
7. Rear left side burner control knob 
8. Rear right side burner control knob 
Service & maintenance instructions 
Service and maintenance only to be carried out by an authorised person 
To replace parts such as burners, valves and electric components, the hotplate must be removed from the 
bench top by releasing the attachment hooks, loosening the attachment screws of each burner, unscrewing 
the hotplate attachments nuts which are visible at the bottom of the surface, removing the hotplate top and 
finally replacing the defective parts. 
Note: if the valves must be replaced, first disassemble the ignitions switches wires. 
It is recommended to replace the valve gaskets each time the valve is replaced, thus ensuring a perfect seal 
between the body and the gas train. 
WARNING: Disconnect power before servicing unit. 
For the location of the wall receptable for the connection of the three-pin earthed plug of the 
appliance, see indications given in Fig. 1- 2 
WARNING: After first installation of the appliance or after any service intervention concerning main 
gas parts of the appliance, make the leak test using water with soap on the gas connections in order 
to verify the correct installation. Do not use fire for gas leak testing. 
Greasing the valves 
If it becomes difficult to operate the valve, it should be greased immediately by following the instructions 
listed below 
1. Disassemble the valve body by loosening the two screws located on the body of the valve. (See Fig. 13). 
2. Extract and clean the seal cone and its housing with a rag soaked with thinners. 
3. Lightly grease the cone with a special grease. 
4. Insert the cone, moving it several times, remove it again, remove the excess grease and make sure that 
the gas passage ways are unobstructed. 
5. Replace all the pieces in reverse order and check that the valve operates correctly. 