User's Guide

3
omlox WTag User Guide
Opening the casing of an omlox WTag and/or replacing any of its
component, including the battery, is prohibited.
omlox WTags only operate (i.e. receive and transmit UWB signals)
within a complete UWB real-time location system BeSpoon
RTLS, which must be professionally installed.
In case omlox WTags, including their batteries, must be disposed of,
they must be collected in compliance with Directive 2012/19/EU (Waste
of Electrical and Electronic Equipment).
2.2. Battery
Improper use of the battery may cause heat, fire, rupture, damage or capacity
deterioration of the battery. In order to ensure a safe and efficient use of omlox
WTag's battery, read the following information and apply the following instruc-
tions carefully.
Nominal capacity 240mAh
Nominal voltage 3.7V
Discharge Cut-off Voltage 2.75V
Charge method CC / CV
(Constant Current / Constant Voltage)
Max charge current 120mA
Charge voltage 4.2 ±0.03V
Max discharge current 120mA
(for continuous discharging mode)
Weight about 7.0g
Temperatures
Charge 0°C to +45°C
Discharge -20°C to +60°C
Storage -20°C to +25°C
Storage relative humidity 65 ±20%
* capacity recovery rate should be more than 80%of initial Capacity
Charge omlox WTags with a charging station approved by BeSpoon.
The omlox WTag was inspected carefully before shipment. However, in the
case any abnormality of bad smell or heat, etc, arises after purchase, please
contact BeSpoon.
For long-term storage, please charge at 0.5C° for about one hour in
advance