• Opening the casing of an omlox WTag and/or replacing any of its
component, including the battery, is prohibited.
• omlox WTags only operate (i.e. receive and transmit UWB signals)
within a complete UWB real-time location system BeSpoon
RTLS, which must be professionally installed.
• In case omlox WTags, including their batteries, must be disposed of,
they must be collected in compliance with Directive 2012/19/EU (Waste
of Electrical and Electronic Equipment).
2.2. Battery
Improper use of the battery may cause heat, fire, rupture, damage or capacity
deterioration of the battery. In order to ensure a safe and efficient use of omlox
WTag's battery, read the following information and apply the following instruc-
tions carefully.
Nominal capacity 240mAh
Nominal voltage 3.7V
Discharge Cut-off Voltage 2.75V
Charge method CC / CV
(Constant Current / Constant Voltage)
Max charge current 120mA
Charge voltage 4.2 ±0.03V
Max discharge current 120mA
(for continuous discharging mode)
Weight about 7.0g
Temperatures
Charge 0°C to +45°C
Discharge -20°C to +60°C
Storage -20°C to +25°C
Storage relative humidity 65 ±20%
* capacity recovery rate should be more than 80%of initial Capacity
• Charge omlox WTags with a charging station approved by BeSpoon.
• The omlox WTag was inspected carefully before shipment. However, in the
case any abnormality of bad smell or heat, etc, arises after purchase, please
contact BeSpoon.
• For long-term storage, please charge at 0.5C° for about one hour in
advance