Service manual

3
POWER SUPPLY REQUIREMENTS
This lift comes with (2) 12 VDC batteries in series to provide a 24 VDC system. A separate 120 VAC power
supply is only required when charging the post. Each post comes equipped with a 120 VAC, 60 HZ receptacle
which accepts a 120 VAC extension cord. The minimum amp draw is 3 amps per post. Use sizes of plug, cord
and power supply as follows:
Plug Requirements:
NEMA Type 5-15 (Female), 125 VAC, 2 Pole, 3 Wire Grounding, 15 Amp Rated.
Cord Requirements:
3 Wire, 125 VAC, 15 Amp Rated, Oil Resistant, Type G, SO, STO, or W. (Maximum Length is 50 feet)
Power Requirements:
115-120 VAC, 2 Pole, 3 Wire Grounding, 60 Hz, 3 Amps minimum per post. Size circuit breaker to NEC and
local codes.
WARNING: Keep in mind that branching extension cords between posts will multiply the amp draw.
(i.e. 6 posts will collectively draw 18 amps).
NOTE THAT THESE POSTS WILL NOT OPERATE AND CHARGE AT THE SAME TIME.
REMOVE THE POWER LEADS TO THE CHARGER RECEPTACLE PRIOR TO LIFT USAGE.