Service manual
21
Maximum Offset Error:
There are limits on how far any post can be out of level from any other post, even when using Single and Pair
overrides. If any post reaches its limits, one of the following screens will be displayed (depending on if the
unit is being used in All, Pair, or Single). The highest and lowest posts will be identified. Raising is only
allowed on the lowest post, Lowering only allowed on the Highest post. These offsets are normally outside
the bounds of normal usage and prevent extreme out of level conditions.
Lock Not Releasing Error:
This screen will only occur during Lowering of the lift. This screen
indicates that one of the locks is not released, and it will prevent the
lift from lowering. This may be due to a lock on the identified post
from being mechanically parked, the solenoid not pulling the lock
back, or the sensor not “seeing” the lock pulled back (sensor may
need to be adjusted). The post that causes this error will be
identified.
i.e. The display to the left shows that post 1 lock is not released.
Loss of Motion Error:
This screen will occur if any post is not sensing motion when a
raise or lowering command is present. This may occur if a post
string-pot is disconnected, malfunctioning, or cable is broken. This
also may occur if the lift is lowering onto an obstruction to prevent
its motion. Press Exit key at post this occurs at to remove message.
(Note: If message remains, then the string-pot is disconnected and
needs to be repaired)
i.e. The display to the left shows that post 4 experienced a loss of
motion while raising or lowering.