Service manual
Left Side of Control Box Right Side of Control Box
MASTER ENCLOSURE PORTS:
1. COMMUNICATION RECEPTACLE – Place where communication cable or dummy
plug connects.
2. 12 VDC AUXILIARY POWER RECEPTACLE – Provided to plug in standard electrical
items that run on 12 VDC, (i.e. Lights)
3. HORN – Sounds when mechanical locks are released. Volume is adjustable.
4. PENDANT RECEPTACLE – Place where hand pendent connects.
5. COMMUNICATION RECEPTACLE CAP – Can also be used to hold spare dummy
plugs.
6. OPERATE LIFT/CHARGE LIFT SWITCH – Turns on Power to post. When post power
is turned off, charging is enabled.
7. 120 VAC CHARGER POWER INLET – Connecting a 120 VAC Power Cord to this
inlet provides power to the dual battery charger.