Specifications
K17
Parker Hannifin Corporation
Pneumatic Division
Wadsworth, Ohio 
www.parker.com/pneumatics
Pneumatic Actuator Products
Air Motors
Air 
Motors
K
Marking of Products
For all P1V-S012, P1V-S020, P1V-S030 and P1V-S060 
For the P1V-S120
  Communatuté Européenne = EU 
CE marking shows that as a manufacturer, Parker Hannifin 
meets the guidelines specified by the EU
  Ex means that this product is intended for use in a 
potentially explosive area
II   stands for the equipment group (I = mines and II = other 
places liable to be endangered)
2GD  stands for equipment category
2G means the equipment can be used in zones 1 and 
2 where there is a risk involving gas, vapour or mist of 
combustible liquids and 2D in zones 21 and 22 where there 
is a risk involving dust .  
2GD means the equipment can be used in zones 1, 2, 21 
and 22.
c  Safe design (prEN 13463-5)
IIC  Explosion group, P1V-S air motors are tested to the highest 
standards in terms of test gases, and can be installed in the 
presence of all gases without restriction.
T6  If equipment is in temperature class T6, the maximum 
surface temperature must not exceed 85°C. (To guarantee 
this, the product has been tested to ensure that the 
maximum is 80°C. This provides a safety margin of 5°K.)
T5  If equipment is in temperature class T5, the maximum 
surface temperature must not exceed 100°C. (To guarantee 
this, the product has been tested to ensure that the 
maximum is 95°C. This provides a safety margin of 5°K.)
(80°C)  Maximum permitted surface temperature on the motor in 
atmospheres containing potentially explosive dust.
X  Note special conditions
  Test certificate number IBExU04ATEXB004 X from IBExU 
Institut für Sicherheitstechnik GmbH, D-09599 Freiberg, 
Germany
For The P1V-S012, P1V-S020, P1V-S030 and 
P1V-S060 Series
The temperature is measured on the metal surface next to the 
seal around the output shaft on all P1V-S012, P1V-S020,  
P1V-S030 and P1V-S060 motors 
II2 GD c IIC T6 (80°C) X
II2 GD c IIC T5 (95°C) X
Seal
Planetary 
Gearbox
Motor Part
45
Planetary
Gearbox
Motor Part
x
Motor      x [mm]
P1V-S020A0011    133
P1V-S020A0006      133 
P1V-S030A0023    146
P1V-S030A0010    147,5
The maximum temperature is reached after approximately 1,5 hours 
of operation, and the difference in temperature between the motor and 
the ambient temperature must not exceed  40 °C. 
If the temperature difference at the seal of a P1V-S012, P1V-S020, 
P1V-S030 or P1V-S060 exceeds 40 °C, you should stop the motor 
immediately and contact Parker Hannifin.   
The following applies to the P1V-S120 series:
The temperature is measured on the metal surface at a point 45 mm 
from the port end of the motor housing, on all P1V-S120.
The maximum temperature is reached after approximately 1,5 hours 
of operation, and the difference in temperature between the motor and 
the ambient temperature must not exceed  55 °C. 
If the temperature difference at this point on a P1V-S120 exceeds 55 °C, 
you should stop the motor immediately and contact Parker Hannifin.  
Motors P1V-S020A0011, P1V-S020A0006, 
P1V-S030A0023 and P1V-S030A0010
Catalog 0900P-E
Temperatures & Marking