b6 10 Professional Balance Charger Microprocessor controlled high-performance rapid charger/discharger with integrated balancer USB PC link and temperature sensor Charge current up to 10A,discharge current up to 5A,1 to 6 series of Lilo/LiFe,1 to 18 cells of NiCd/NiMH,2 to 24V of Lead-acid(Pb) b6 10 Instruction Manual All specifications and figures are subject to change without notice. Printed in China ©2010 www.imaxrc.
Features Introduction Introduction Thank you for purchasing the B6 10 Pro Charger by ImaxRC.You get a rapid charger/discharger with integrated balancing circuit,which is computerised with a high performance microprocessor and specialised operating software.It can maintain your battery at its best condition and also control them safely please read this operating manual completely and attentively as it contains a wide variety of specific programming and safety information.
Warnings and safety notes Warnings and safety notes Never leave the charge unsupervised when it is connected to its power supply.If any maifunction is observed immediately terminate the process and refer to the operation manual. Keep away the unit from dust ,damp,rain,heat direct sunshine and vibration.Do not drop it. The circuit of the unit is designed to be power by a 12V DC only.
Program flow chart Warnings and safety notes the battery you also have to pay attention on the process same as charging.To avoid the battery becoming deep-discharged,set the final discharge voltage correctly.Lithium batteries should not be deep-discharged,set the final discharge voltage,as this leads to a rapid loss of capacity or a total failure.Generally,you do not need to discharge Lithium battery voluntarily. -Some rechargeable batteries are said to have a memory effect.
Initial parameter set up(Users set program) Initial parameter set up(Users set program) B6 10 Pro will be operated with the default value of the essential user settings when it is connected to a 12V battery for the first time.The screen displays the following information in sequence and the user can change the value of parameter on each screen. When you are willing to alter the parament value in the program,press Start/Enter key to make it blink then change the value with INC>or
Lithium battery(Lilo/LiPo/LiFe)program Lithium battery(Lilo/LiPo/LiFe)program Lithium battery(Lilo/LiPo/LiFe)program These programs are only suitable for charging and discharging Lithium batteries with a nominal voltage of 3.3v,3.6v and3.7v per cell.These batteries need to adopt different charge technique is termed constant voltage(CV) and constant current(CC) method.The charge current varies according to the battery capacity and performance.
Lithium battery(Lilo/LiPo/LiFe)program Lithium battery(Lilo/LiPo/LiFe)program 'FAST' charging Lithium battery Discharging Lithium battery The charging current getting smaller as the process goes to the near end term of Lithium battery charging.To finish charging process earlier,this program eliminate certain term of CV process.Actualy,the charging current will goes to 1/5 from the initial value to end the process while the normal charging goes to 1/10 during CV term.
NiMH/NiCd battery(Lilo/LiPo/LiFe)program These programs are for charging or discharging NiMH (Nickel-Metal-Hydride) or NiCd (Nickel-Cadmium) battery commonly used for R/C model applications.To alter the value at the display,press Start/Enter key to make it blink then change the value using INC> or
Pb(lead-sulphuric acid)battery program Save Data program This is programmed for charging pb(lead-acid)battery with nominal voltage from 2 to 24v.Pb batteries are totally different from NiCd or NiMH batteries.They can only deliver relatively lower current compare to their capacity,and similar restrictions definitely apply to charge.So the optimal charge current will be 1/10 of the capacity.Pb batteries must not be charged rapidly.Always follow the instruction is supplied by the manufacturer of battery.
Load Data program Various information during the process This program calls back the data that was stored at 'Save Data'program. Various information during the process To load the data,press Star/Enter key once to blink the data number field and select the number using INC> or
Warning and error messages Glossary of terms B6 10 Pro incorporates a various functions of protective and monitoring the system to verify functions and the state of its electronics.In any case of occurring error,the screen displays the cause of error that is self-explanatory with audible sound. REVERSE POLARITY The output is connected to a battery with incorrect polarity.
Balancing the multi Lithium battery packs Maximum circuit power chart Balancing the multi Lithium battery packs Maximum circuit power chart You can charge and balance several Lithium batteries at the same time,by using optional'Muti-board adaptor'(*).Please note that the battery packs being charged should have same capacity and cell-count.
Specifications/Warranty and service Specifications Operating voltage range: Circuit power: Charge current range: Discharge current range: Current drain for balancing Lipo: NiCd/NiMH battery cell count: Lithium battery cell count: Pb battery voltage: Weight: Dimensions: 10.0-18.0 Volt max.200Watts(charging) max.25Watts(discharging) 0.1-10.0A 0.1-5.