Installation Guide

ALP AMBIENT LIGHT PANEL INSTALLATION INSTRUCTIONS
FOR USE WITH
BEST LINERS MODELS L5230, L7030, L7036, L7048, L2936, L2942, L3848, L3860, L3336, L3342, L4548 AND L4560 ONLY
INSTALLATION DU PANNEAU DÉCLAIRAGE DAMBIANCE ALP - NE CONVIENT QUAUX RECOUVREMENTS DARMOIRE BEST DE MODÈLE L5230, L7030,
L7036, L7048, L2936, L2942, L3848, L3860, L3336, L3342, L4548
ET L4560 SEULEMENT
INSTRUCCIONES PARA LA INSTALACIÓN DEL TABLERO DE ILUMINACIÓN AMBIENTAL ALP SÓLO PARA REVESTIMIENTOS BEST DE LOS MODELOS L5230, L7030,
L7036, L7048, L2936, L2942, L3848, L3860, L3336, L3342, L4548
Y L4560
E
NGLISH READ AND SAVE THESE INSTRUCTIONS - INSTALLER: LEAVE THIS INSTRUCTION SHEET WITH THE HOMEOWNER.
THIS KIT CONTAINS: • ONE ALP AMBIENT LIGHT PANEL WITH ONE GROMMET
1. I
F ALREADY INSTALLED
, REMOVE THE FRONT PANEL SECTION (A)
FROM THE CUSTOM HOOD BASE
.TAKE CARE NOT TO SCRATCH MAIN LINER PLATE WHEN REMOVING
FRONT PANEL SECTION OF LINER
.(SEE FIGURE
.)
NOTE: D
O NOT DISCARD THE SCREWS, KEEP THEM FOR FUTURE USE.
2. TURN OFF POWER AND LOCK OUT SERVICE PANEL BEFORE WIRING AMBIENT LIGHT PANEL
.
3. R
UN A 2-
WIRE PLUS GROUND POWER CABLE
(NOT SUPPLIED) TO AMBIENT LIGHT PANEL LOCATION THROUGH A HOLE IN THE BOTTOM OF THE CUSTOM HOOD BASE
LOCATED WITHIN THE GREY ZONE AS SHOWN
.(S
EE FIGURE
.)
NOTE: I
F THE MAIN LINER PLATE COVERS THE BOTTOM OF THE CUSTOM HOOD WHERE THE POWER CABLE WILL ENTER, YOU WILL NEED TO PROVIDE A HOLE THROUGH
THE MAIN LINER PLATE AS WELL
.TO DO THIS, DISASSEMBLE THE MAIN LINER PLATE AND INSERT (WITH INTERNAL BLOWER IF APPLICABLE) FROM THE CUSTOM
HOOD
.PUNCH OR DRILL A 5/8’ DIAMETER HOLE THROUGH THE MAIN LINER PLATE IN THE LOCATION SHOWN (GREY ZONE IN FIGURE ). DEBURR THE SHEET METAL HOLE.
P
ARTIALLY REASSEMBLE THE MAIN LINER PLATE AND TRACE THE 5/8’’ METAL HOLE ONTO THE BOTTOM OF THE CABINET WITH A PENCIL. REMOVE THE MAIN LINER PLATE AGAIN
AND DRILL A 3/4’’ DIAMETER MINIMUM HOLE IN THE BOTTOM OF THE CUSTOM HOOD, LOCATED ON THE SAME CENTERPOINT AS THE HOLE IN THE MAIN LINER PLATE. REINSTALL
MAIN LINER PLATE AND INSERT
. INSERT THE PLASTIC GROMMET (PROVIDED) THROUGH HOLE IN MAIN LINER PLATE PRIOR TO PASSING THE ELECTRICAL CABLE THROUGH IT.
(S
EE FIGURE
.)
S
TUB OUT ENOUGH LENGTH OF CABLE BELOW THE CUSTOM HOOD TO PERFORM THE AMBIENT LIGHT PANEL ELECTRICAL CONNECTION.
NOTE: WHEN DRILLING HOLE, PROTECT COOKTOP AND COUNTERTOP SURFACES.
4. R
EMOVE THE 4 SCREWS RETAINING THE SMALL PLATE COVERING THE ELECTRICAL COMPARTMENT OF THE AMBIENT LIGHT PANEL.(SEE FIGURE .)
5. R
EMOVE THE WIRING KNOCKOUT LOCATED ON THE AMBIENT LIGHT PANEL END AND INSTALL APPROVED ELECTRICAL CABLE CLAMP
(NOT SUPPLIED). PASS THE POWER CABLE THROUGH
THE CABLE CLAMP AND TIGHTEN THE WIRE CLAMP TO SECURE THE POWER CABLE
.(SEE FIGURE .)
6. C
ONNECT THE POWER CABLE TO THE AMBIENT LIGHT PANEL WIRES USING WIRE CONNECTORS (NOT SUPPLIED) AS FOLLOWS: WHITE TO WHITE (B), BLACK TO BLACK (C), AND
GREEN
OR BARE WIRE UNDER
GREEN GROUND SCREW (D)
INSIDE THE AMBIENT LIGHT PANEL
.(S
EE FIGURE
.)
7. R
EINSTALL THE SMALL PLATE COVERING THE ELECTRICAL COMPARTMENT.
8. S
LIDE THE AMBIENT LIGHT PANEL (E) FORWARD INTO THE NOSE OF THE CUSTOM HOOD BASE.TAKE CARE NOT TO SCRATCH MAIN LINER PLATE WHEN INSTALLING
AMBIENT LIGHT PANEL
.ASSEMBLE IT TO THE CUSTOM HOOD BASE, USING ONE SCREW PER SCREW HOLE.(SEE FIGURE
.)
9. R
ESTORE POWER AND TEST THE ON/OFF ROCKER SWITCH LIGHT CONTROL.
THIS AMBIENT LIGHT PANEL INCLUDES SHIELDED HALOGEN LAMPS. (120V, 50W, TYPE GU10). REPLACEMENT LAMPS MUST BE MAX. 50W TYPE GU10 SHIELDED (120V).
TO REMOVE TRIM RINGS, GENTLY PUSH UPWARD AND TURN COUNTERCLOCKWISE.TO REMOVE LAMPS, GENTLY PUSH UPWARD AND TURN COUNTERCLOCKWISE.INSTALL LAMPS BY
PLACING THE BULB LEADS INTO THEIR GROOVES IN THE SOCKET AND GENTLY PUSH UPWARD AND TURN CLOCKWISE UNTIL SECURED
.REINSTALL TRIM RINGS BY GENTLY PUSHING UPWARD
AND TURNING CLOCKWISE UNTIL SECURED
.
FOR DETAILS ON CLEANING, SEE INSTRUCTIONS INCLUDED WITH INSERT OR POWER PACK.
F
RANÇAIS LIRE ET CONSERVER CES INSTRUCTIONS - INSTALLATEUR : LAISSER CETTE FEUILLE DINSTRUCTION AU PROPRIÉTAIRE.
CET ENSEMBLE COMPREND :• UN PANNEAU DÉCLAIRAGE DAMBIANCE ALP ET UN PASSE-FILS
SUITE AU VERSO
WARNING
WARNING
Risk of electrical shock. Electrical wiring must be done by qualified personnel in accordance with all applicable codes and standards. Turn off power and lock out service panel before
installing, wiring, or servicing this product. This unit must be grounded.
3''
2''
Drilling zone
BOTTOM VIEW / VUE DU DESSOUS / DEBAJO
FRONT / AVANT / FRENTE
!
grommet
HA0034
AVERTISSEMENT
Risque de choc électrique. Le raccordement électrique doit être effectué par du personnel qualifié conformément aux codes et standards. Avant d’installer, d’effectuer le branchement ou
l’entretien de ce produit, coupez l’alimentation électrique au panneau de service et verrouillez-le. Cet appareil doit être mis à la terre.
!
WARNING
!
When cutting or drilling into wall, do not damage electrical wiring and other hidden utilities.
HA0020
A
CAUTION
Before installing, remove the protective plastic film from all parts. Also, remove tape on trim rings.
WARNING
!
The ambient light panel power cable (not supplied) must be minimum 90°C (194°F) supply conductors.
HA0036
HE0029
B
C
D
HA0020
E
HD0078
ATTENTION
Retirer le film de plastique protecteur sur toutes les pièces avant de procéder à l’installation. Aussi, enlever le ruban gommé sur les anneaux de chrome.
SERVICE PARTS
V05921 Shielded Halogen Lamp 120V, 50W, GU10
V05917 Lamp Socket
V02563 Rocker Switch
B02009102 Trim Ring
In order to prevent the risk of personal injury, do not install a lamp identified for use only in enclosed fixtures.
!

Summary of content (2 pages)