22. OPERATION
Always turn your blower on before you begin cooking to establish an airflow in the kitchen. Let the blower run for a few minutes to clear
the air after you turn off the range.
HC0016
SPEED 1 2 3 4
BA C D E
A. BLOWER DELAY-OFF BUTTON:
When blower is on, press the delay-off button to activate the delay-off function. The corresponding speed indicator LED will start flashing to
indicate this function is activated. The fan will continue to operate for 10 minutes and will stop automatically. To cancel the delay-off function,
press the blower delay-off button once again; the blower will then work in normal mode.
NOTE: The blower speed can be increased—or decreased—during delay-off mode without starting another 10-minute cycle.
B. ON
BLOWER/SPEED CONTROL BUTTON:
Press this button to turn on the blower at the last selected speed. To change the blower speed, press the button again until the desired
speed is obtained. Press and hold this button for 2 seconds to decrease the speed level down by one increment. Possible decreases are
then: 4 to 3; 3 to 2; 2 to 1 and 1 to OFF.
NOTES: 1. Each time you press the speed control button, the speed changes by increments of 1 (e.g.: speed 1 to speed 2, to speed 3,
and then speed 4). From the fourth speed, the speed goes down to level 1.
2. The last speed used is kept in memory so that when the unit is turned on, it will return to the last setting except the fourth, the
next time the blower will be turned on, it will return to speed 3. The memorized speed level is also synced with the optional
remote control.
HEAT SENTRY™
The power pack is equipped with a protective device that activates when excessive heat is detected inside the power pack. During the Heat
Sentry activation, this device takes control of the blower and set it on speed 4; the speed 4 button LED will flash. The blower will remain
on speed 4 until the heat is back to normal, it then returns to the speed previously selected.
C. OFF
BLOWER/FILTER MAINTENANCE BUTTON:
Press this button to turn off the blower. Pressing this button also cancels the delay-off function (if activated).
NOTE: After 30 hours of operation, the 4 blower speed lights will flash 30 seconds to indicate the filters need to be cleaned in order to
maintain efficient power pack operation. Pressing this button will reset the code to indicate that maintenance has been completed.
D. OFF
LIGHTING:
Press this button to turn the lamps off.
E. ON
LIGHTING:
Press this button to turn the lamps on; all 3 control LED will light on.
NOTE: There is only one light setting.
WARNING
!
The HEAT SENTRY can start the blower during a range top fire or other excessive heat situations even if the power
pack is turned off. In this case, it is impossible to turn the blower OFF with blower button. If you must stop the blower
on CP55IQ/CP57IQT series models: set the main power switch located behind the baffle filters in OFF position, if
it is possible to do safely (see illustration below). For CP57E series models: do it from the main electrical panel.
A) Blower delay-off button
B) ON blower/Speed control button
C) OFF blower/
Filter maintenance button
D) OFF lighting
E) ON lighting
MAIN
POWER
SWITCH
CP55IQ AND
CP57IQT