Installation Guide
9
10. INSTALL THE 10” ADAPTER (CP57IQT SERIES ONLY)
Using 2 no. 8 x 3/8” screws from parts bag, assemble the adapter on the top of the power pack.
Seal all joints with metal foil duct tape to eliminate air leaks.
NOTE: For a non-ducted installation, do not install the 10” in-line damper.
Install 10” in-line damper inside the vertical ductwork that will be attached to power pack. Do not
install in a horizontal ductwork or it will not open and close properly. Remove shipping tape if
present. Secure the damper to the duct with 3 no. 8 sheet metal screws (not provided). Ensure
damper opens and closes freely. Seal all joints with metal foil duct tape to eliminate air leaks.
10" min.
recommended
HJ0073A
11. INSTALL THE 10” IN-LINE DAMPER
(CP57IQT AND CP57E SERIES, DUCTED INSTALLATION ONLY)
HJ0026
MOUNTING SCREW LOCATIONS