Installation Parts Guide

Cattura Downdraft Installation Parts Guide (Revision February 2020)
3
8
Left or Right / Internal / Under
Floor
For Clear Front
Ref. Page 10 spec sheet
D49M (30-36-48)
PF6 - Internal blower
ATKD30SB/30BLS, ATKD36SB/36BLS, ATKD48SB – Range trim kit SS
or Blk SS (If slide-in range)
AVDKD219 (1-7/8” x 19” rectangular adaptor) AEED2 (optional
rectangular duct) AVDKD8 – Transition to 8’’ round
408 – 8” Rd Duct / 432 - 8” Elbow (as required) 643 8’’ Rd. wall cap
9
Left or Right / Exterior or In-Line
For Clear Front
Ref. Page 14 spec sheet
For 48” Pro slide in range or
applications with grills
recommend using dual outlet
and EB15.
D49M (30-36-48)
EB9, EB12, EB15, ILB11 – Exterior or in-line blower
ATKD30SB/30BLS, ATKD36SB/36BLS, ATKD48SB – Range trim kit SS
or Blk SS (If slide-in range)
AVDKD219 (1-7/8” x 19” rectangular adaptor) AEED2 (optional
rectangular duct) AVDKD10 – Transition to 10’’ round (for single
outlet)
2 X AVDKD8 – Transition to 8’’ round (for dual outlet)
ATKD8810 – “Y” Transition Two 8” in to one 10” (for dual
outlet), 441 10’’ Rd wall cap
Option
BELOW Installation
Parts needed
10
Below vent / Internal / Under
Floor
Ref. Page 12 spec sheet
D49M (30-36-48)
PF6 - Internal blower
ATKD30SB/30BLS, ATKD36SB/36BLS, ATKD48SB – Range trim kit SS
or Blk SS (If slide-in range)
AVDKD8 – Transition to 8’’ round
408 – 8” Rd Duct / 432 - 8” Elbow (as required) 643 8’’ Rd. wall cap
ANKD – Recirculation kit (optional)
11
Below vent / Exterior or In-Line
Ref. Page 15 spec sheet
For 48” Pro slide in range or
applications with grills
recommend using dual
outlet and EB15.
D49M (30-36-48)
EB9, EB12, EB15, ILB11 – Exterior or in-line blower
ATKD30SB/30BLS, ATKD36SB/36BLS, ATKD48SB – Range trim kit SS
or Blk SS (If slide-in range)
AVDKD10 – Transition to 10’’ round
410 – 10” Rd Duct / 418 - 10” Elbow (as required) /
441 10’’ Rd wall cap