Installation Parts Guide
Cattura Downdraft Installation Parts Guide
March 31, 2016 2
5
Rear / Internal / Under Floor
For Clear Front
For 48” Pro slide in range or
applications with grills
recommend using Option 9
with dual outlet and EB15.
D49M (30-36-48)
PF6 - Internal blower
ATSKD30,36,48 Gas cooktop seal kit- (If gas cooktop)
ATKD30,36SB – Range trim kit (If slide-in range)
408 – 8” Rd Duct / 432 - 8” Elbow (as required)
AEWD5 – 5’ Ext. cable for electrical panel (use up to two if
PF6 blower is mounted more than 4 feet away from
downdraft)
6
Rear / External
For Clear Front
For 48” Pro slide in range or
applications with grills
recommend using Option 9
with dual outlet and EB15.
D49M (30-36-48)
EB15 or ILB11 – External or in-line blower
ATSKD30,36,48 Gas cooktop seal kit- (If gas cooktop)
ATKD30,36SB – Range trim kit (If slide-in range)
AVDKD10 – Transition to 10’’ round
410 – 10” Rd Duct / 418 - 10” Elbow (as required)
AEWD5 – 5’ Ext. cable for electrical panel (use up to two if
panel is mounted more than 2 feet away from downdraft)
7
Lft or Rht / Internal / In Cabinet
For Clear Front
For 48” Pro slide in range or
applications with grills
recommend using Option 9
with dual outlet and EB15.
D49M (30-36-48)
PF6 - Internal blower
ATSKD30,36,48 Gas cooktop seal kit- (If gas cooktop)
ATKD30,36SB – Range trim kit (If slide-in range)
AVDKD8 – Transition to 8’’ round
408 – 8” Rd Duct / 432 - 8” Elbow (as required)
AEWD5 – 5’ Ext. cable for electrical panel (use up to two if:
blower is mounted more than 2 feet away from downdraft on
the right - if going left you will need to order a minimum of
one)
ANKD – Recirculation kit (optional)
8
Lft or Rht / Internal / Under
Floor
For Clear Front
For 48” Pro slide in range or
applications with grills
recommend using Option 9
with dual outlet and EB15.
D49M (30-36-48)
PF6 - Internal blower
ATSKD30,36,48 Gas cooktop seal kit- (If gas cooktop)
ATKD30,36SB – Range trim kit (If slide-in range)
AVDKD8 – Transition to 8’’ round
408 – 8” Rd Duct / 432 - 8” Elbow (as required)
AEWD5 – 5’ Ext. cable for electrical panel (use up to two if
PF6 blower is mounted more than 4 feet away from
downdraft)
9
Lft or Rht / External or In-Line
For Clear Front
For 48” Pro slide in range or
applications with grills
recommend using dual outlet
and EB15.
D49M (30-36-48)
EB12, 15, ILB11 – External or in-line blower
ATSKD30,36,48 Gas cooktop seal kit- (If gas cooktop)
ATKD30,36,48SB – Range trim kit (If slide-in range)
AVDKD10 – Transition to 10’’ round (for single outlet)
2 X AVDKD8 – Transition to 8’’ round (for dual outlet)
ATKD8810 – “Y” Transition Two 8” in to one 10” (for dual
outlet)
AEWD5 – 5’ Ext. cable for electrical panel (use up to two if
panel is mounted more than 2 feet away from downdraft)