Parts Guide

Cattura Downdraft Installation Parts Guide
March 31, 2016 2
5
Rear / Internal / Under Floor
For Clear Front
For 48” Pro slide in range or
applications with grills
recommend using Option 9
with dual outlet and EB15.
D49M (30-36-48)
PF6 - Internal blower
ATSKD30,36,48 Gas cooktop seal kit- (If gas cooktop)
ATKD30,36SB Range trim kit (If slide-in range)
408 8” Rd Duct / 432 - 8” Elbow (as required)
AEWD5 5’ Ext. cable for electrical panel (use up to two if
PF6 blower is mounted more than 4 feet away from
downdraft)
6
Rear / External
For Clear Front
For 48” Pro slide in range or
applications with grills
recommend using Option 9
with dual outlet and EB15.
D49M (30-36-48)
EB15 or ILB11 External or in-line blower
ATSKD30,36,48 Gas cooktop seal kit- (If gas cooktop)
ATKD30,36SB Range trim kit (If slide-in range)
AVDKD10 Transition to 10’’ round
410 10” Rd Duct / 418 - 10” Elbow (as required)
AEWD5 5’ Ext. cable for electrical panel (use up to two if
panel is mounted more than 2 feet away from downdraft)
7
Lft or Rht / Internal / In Cabinet
For Clear Front
For 48” Pro slide in range or
applications with grills
recommend using Option 9
with dual outlet and EB15.
D49M (30-36-48)
PF6 - Internal blower
ATSKD30,36,48 Gas cooktop seal kit- (If gas cooktop)
ATKD30,36SB Range trim kit (If slide-in range)
AVDKD8 Transition to 8’’ round
408 8” Rd Duct / 432 - 8” Elbow (as required)
AEWD5 5’ Ext. cable for electrical panel (use up to two if:
blower is mounted more than 2 feet away from downdraft on
the right - if going left you will need to order a minimum of
one)
ANKD Recirculation kit (optional)
8
Lft or Rht / Internal / Under
Floor
For Clear Front
For 48” Pro slide in range or
applications with grills
recommend using Option 9
with dual outlet and EB15.
D49M (30-36-48)
PF6 - Internal blower
ATSKD30,36,48 Gas cooktop seal kit- (If gas cooktop)
ATKD30,36SB Range trim kit (If slide-in range)
AVDKD8 Transition to 8’’ round
408 8” Rd Duct / 432 - 8” Elbow (as required)
AEWD5 5’ Ext. cable for electrical panel (use up to two if
PF6 blower is mounted more than 4 feet away from
downdraft)
9
Lft or Rht / External or In-Line
For Clear Front
For 48” Pro slide in range or
applications with grills
recommend using dual outlet
and EB15.
D49M (30-36-48)
EB12, 15, ILB11 External or in-line blower
ATSKD30,36,48 Gas cooktop seal kit- (If gas cooktop)
ATKD30,36,48SB Range trim kit (If slide-in range)
AVDKD10 Transition to 10’’ round (for single outlet)
2 X AVDKD8 Transition to 8’’ round (for dual outlet)
ATKD8810 “Y” Transition Two 8” in to one 10” (for dual
outlet)
AEWD5 5’ Ext. cable for electrical panel (use up to two if
panel is mounted more than 2 feet away from downdraft)