Specification Sheet
Page 9
INTERNAL BLOWER (PF6) - REMOTE MOUNTED - SIDE OR REAR OUTLET
• Ducting connected to right side
of Downdraft
(Ducting connects to left side or rear
of downdraft in same manner.)
• Flex Blower mounted in a side
cabinet or other remote, in-line
location
• Ducted to Wall Cap or Non-Duct
Recirculation Kit
MODEL AVDKD8
1-7/8-inch to 8-inch
Round Transition
(sold separately)
Electrical Panel
(Can be mounted in
remote location.)
MODEL AEWD5
5-foot Extension Cable
(sold separately)
(Only required if Electrical
Panel is mounted in a remote
location - more than 2-feet
away from downdraft. Use up to
2 Extension Cables
connected together.)
MODEL AEDD2 *
1-7/8-inch x 19-inch
Rectangular Duct
(sold separately)
(Only required to extend
duct along back
of cabinet.)
MODEL AVDKD219 *
1-7/8-inch x 19-inch
Rectangular Transition
(sold separately)
(Only required to extend
duct along back
of cabinet.)
MODEL PF6
Flex Blower
(sold separately)
(Mounted in
remote location.)
MODEL 643 *
8-inch Round
Wall Cap
MODEL 408 *
8-inch Round
Straight Duct
* As required - sold separately.
MODEL PF6
Flex Blower
(sold separately)
(Mounted in
side cabinet.)
MODEL 423 *
8-inch Round
Elbow
MODEL
408 *
8-inch
Round
Straight
Duct
MODEL
ANKD
Non-Duct
Recirculation Kit
with kickspace grille
(sold separately)
(Only required for
Non-Duct applications.
“Front” discharge shown.
Kit can also be rotated
for “Left” , “Right” or
“Rear” discharge.)