Specifications

Page 11
Downdraft Ventilators
OPERATION
Press this BUTTON… when CHIMNEY is… and BLOWER is… RESULT
Up/Down Down Off Chimney rises / Blower turns On to last speed used
Up/Down Up On or Off Chimney lowers / Blower turns Off
High [ 3 ] Up On / Low or Med Blower speed to High.
High [ 3 ] Up On / High Blower turns Off / Chimney remains Up
High [ 3 ] Down Off No action
Med [ 2 ] Up On / Low or High Blower speed to Med
Med [ 2 ] Up On / Med Blower turns Off / Chimney remains Up
Med [ 2 ] Down Off No action
Low [ 1 ] Up On / Med or High Blower speed to Low
Low [ 1 ] Up On / Low Blower turns Off / Chimney remains Up
Low [ 1 ] Down Off No action
Delay * Up On / High Blower on High 5 min. > Low 5 min. > Off
Chimney remains Up / Delay LED flashes & Speed LED’s illuminate
Delay * Up On / Med Blower on Med 5 min. > Low 5 min. > Off
Chimney remains Up / Delay LED flashes & Speed LED’s illuminate
Delay * Up On / Low Blower on Low 5 min. > Off (all LED’s Off)
Chimney remains Up / Delay LED flashes & Low LED illuminates
Delay * Up On / in Delay Mode Delay Mode cancelled
Delay * Up or Down Off No action
* Heat Sentry is disabled in Delay mode
When this BUTTON
LED is illuminated and CHIMNEY is… and BLOWER is… RESULT
Filter Up or Down On or Off Filter LED illuminates as a reminder to clean Filters (approx. every 30 hours).
Pressing Filter Button turns Off illuminated Filter LED and resets Filter-use
timer.
Press this BUTTON… when CHIMNEY is… and BLOWER is… RESULT
Filter Up or Down On or Off Pressing Filter button when Filter LED is not illuminated - No action
When this BUTTON
LED is flashing… and CHIMNEY is… and BLOWER was… RESULT
Med [ 2 ] or High [ 3 ] Up On / Low or Med a. Exhaust temperature is higher than anticipated - Heat Sentry mode activated.
LED flashing b. Blower increases to next highest speed.
c. Blower speed LED flashes on / off.
d. Blower speed may increase, decrease, or stay at current speed based on
exhaust air temperature.
e. When Blower speed returns to original setting - Blower speed LED stops
flashing.
f. Unit no longer in active Heat Sentry mode.
Press this BUTTON
and hold for 1 second… when LED is… and BLOWER is… RESULT
Med [ 2 ] Flashing On / any speed Heat Sentry mode disabled. **
High [ 3 ] Flashing On / any speed Heat Sentry mode disabled. **
** Press any button to re-active Heat Sentry.