5
2. PREPARE INSTALLATION
Either an interior or exterior blower or in-line blower may be used with this insert. The insert model PIK33 or PIK45 must be installed
with blower models P5, P8, ILB3, ILB6, ILB9, ILB11, EB6, EB9, EB12 or EB15 only. Other blowers cannot be substituted. (Blowers sold
separately).
Plan where and how the ductwork will be installed. Access to the top of the hood is preferred for connection of ductwork. As an alternative,
flexible metal ductwork may be used.
If installing in-line blower, refer to instructions packed with in-line blower and follow steps 1 up to 8, 13, 14, 16, 17, 19 and up of
this manual.
Install proper-sized ductwork, elbows and roof or wall cap for the type of blower you are installing. Use round ductwork, with a short section
(about 4’ expanded) of flexible metal duct (optional) for attachment to the transition. Use screws to attach flexible metal duct to the rigid
duct. Use 2" metal foil duct tape to seal duct joints.
The minimum hood distance above cooktop must not be less than 24". A maximum of 30" above cooktop is highly recommended
for best capture of cooking impurities.
Distances over 30" are at the installer and users discretion.
M
ODEL P5 (SINGLE) OR
P8 (
DOUBLE) INTERIOR BLOWER
T
YPICAL DUCTWORK
WARNING
!
When performing installation, servicing or cleaning the unit, it is recommended to wear safety glasses and gloves.
NOTE: Before proceeding to the installation, check the contents of the box. If items are missing or damaged, contact the manufacturer.
Make sure that the following items are included:
- Insert
- Accessories: Baffle filters (3 for PIK33 model, 4 for PIK45 model)
Baffle filter handles (3 for PIK33 model, 4 for PIK45 model)
Shielded halogen bulbs (120 V, 50 W, MR16 or PAR16 with GU10 base)
Bag of parts including: 4 lock nuts, 1 wire clamp, 8 no. 8 x 3/4" standard screws, 2 wire connectors,
2 no. 6 x 1/2" standard screws, 8 no. 8 x 3/8" screws. Discard items not used.
Parts sold separately:
- Interior blower Model P5 includes blower, rough-in kit, flow deviator and 3¼" x 10" adapter
- Interior blower Model P8 includes blower, rough-in kit, flow deviator and 3¼" x 10" adapter and 3¼" x 14" adapter
- In-line blower assembly ILB3, ILB6, ILB9 or ILB11 (all include rough-in plate and transition)
- Exterior blower assembly EB6, EB9, EB12 or EB15 (all include rough-in plate)
- Custom hood liner Model L3336S, L3342S, L4548S, L4554S or L4560S (optional)
- Ambient light panel Model ALP36, ALP42, ALP48, ALP54 or ALP60 (optional)
- Backsplash RMP Series (optional)
- WCPI Remote control (optional)
- Transitions, ducts (rigid and flexible), elbows, dampers, wall and roof caps. Refer to page 3 and 4 for a complete list of venting options
and model numbers.
NOTE: During installation, protect countertop and/or cooktop.
1. SELECT BLOWER OPTION AND INSTALL DUCTWORK
Insert with
interior blower
Roof cap
Wall
cap
HH0038A
7” or 8” round ducts
with 7” or 8” round
metal flex. duct (optional)
3 1/4” x 10” to 7” or 8” transition
or 3 1/4” x 14” to 8” transition
24” minimum
above cooking surface
MODEL EB6, EB9, EB12 OR EB15
E
XTERIOR BLOWER TYPICAL DUCTWORK
Insert with
exterior blower
10” round duct
Exterior blower
HH0039A
24” minimum
above
cooking surface
10” round metal
flex. duct
(optional)
MODEL ILB3, ILB6, ILB9 OR ILB11
I
N-LINE BLOWER TYPICAL DUCTWORK
In-line blower
10” round duct
HH0058A
24” minimum
above
cooking surface
10” round metal
flex. duct
(optional)
Roof cap
Wall
cap
Insert