PIK33 PIK45 Installation Guide 05862 REV-18
9
13. CONNECT WIRING (ALL BLOWERS)
Position insert below the installed custom hood. Pull cable through hole in top of insert.
WARNING
!
Risk of electric shock. Electrical wiring must be done by qualified personnel in accordance with all applicable
codes and standards. Before connecting wires, switch power off at service panel and lock service disconnecting
means to prevent power from being switched on accidentally.
INTERIOR BLOWER: Remove the cable knock-out on the top of the rough-in plate. Remove
rough-in plate wiring cover. Place the wire clamp in the knock-out
hole, insert the cable through the wire clamp in the rough-in plate
wiring box. Tighten the wire clamp to secure the cable.
Connect cable into wiring box using provided wire connectors.
Connect wires as follow: BLACK to BLACK, WHITE to WHITE and
GREEN or bare wire under ground screw. DO NOT FORGET TO
CONNECT THE GROUND. Reinstall wiring cover.
HD0007
GROUND SCREW
IN-LINE OR EXTERIOR BLOWER: Remove rough-in plate wiring cover and connect wiring (see instructions included with in-line or
exterior blower).
14. INSTALL THE ROUGH-IN PLATE (ALL BLOWERS)
HD0042
INTERIOR BLOWER: Carefully install the rough-in plate inside the top of
the insert with 4 lock nuts. See picture at right.
IN-LINE OR EXTERIOR BLOWER: Refer to instructions included with ILB3, ILB6, ILB9, ILB11, EB6, EB9, EB12 or EB15 rough-in kit.
Secure the rough-in plate inside the top of the insert with 4 lock nuts.
15. INSTALL THE TRANSITION (INTERIOR BLOWER)
Slide the transition over the adapter/damper. Seal the transition to the adapter/damper
using metal foil duct tape.
HD0091