EXTERNAL BLOWER
PROGRAMMING MODE PROCEDURE (WC34E)
The range hood is designed to work with
several different blower models. Before
using, the control must first be programmed
to your blower model, in order to achieve
proper operating speeds.
From the chart below:
1. Find the SETUP number that
corresponds to the blower model that is
installed with your range hood.
2. The control is factory-preset to SETUP
3. If your blower model is listed under
SETUP 3, no programming is required
and the range hood is ready to use.
SETUP 1 SETUP 2 SETUP 3
(default)
BLOWER
MODEL
NUMBER
EB6
ILB3
ILB6
EB12
EB15
ILB9
EB9
ILB11
3. To program blower models listed under
SETUP 1 and 2:
A) Power must be supplied to the
hood. The blower and lights must be
turned off.
B) Press and hold OFF and ON/+
for 5 seconds. The Blower LED
Indicators will flash 3 times. Then
only the LED will stay lit. After 1
second, the Blower LED Indicators
will show the current setting as
follows:
°°°
SETUP 1
°
°
SETUP 2
° ° °
SETUP 3
C) To select the proper SETUP:
Press OFF/- or ON/+ to select the
desired SETUP.
D) Once the proper SETUP is found:
Press ON to memorize the setting,
or wait 15 seconds and the program
will automatically exit and store the
SETUP.