Spec Sheet
WC35E SERIES WIRING
WC35E SERIES
MOUNTING
a. Minimum hood distance above cook top must not be less than 24”. A maximun of 30” above
cook top is highly recommended for best capture of cooking impurities. Distances over 30” are
at the installer and user’s discretion; and if ceiling height and flue length permit.
b. Requires optional 10-ft. to 11-ft. flue extension, ducted model AEWC345IQSB.
HOOD DISTANCE ABOVE 36” HIGH COOK TOP (see note below)
30”
MOUNTING BRACKET CENTER HOLE LOCATION ABOVE 36” HIGH COOK TOP
CEILING
HEIGHT
8 FEET
24” 25” 26” 27” 28” 29”
WOOD CROSS
SUPPORT BEHIND
DRYWALL
DRYWALL
DUCTED
DUCT
METHOD
FRAMING
BEHIND WOOD
CROSS SUPPORT
3-1/2”
3-1/2”
2-3/16”
9 FEET
DUCTED
10 FEET
(see note b.)
37-7/8” 38-7/8” 39-7/8” 40-7/8” 41-7/8” 42-7/8” 43-7/8”
--- --- --- 40-7/8” 41-7/8” 42-7/8” 43-7/8”
37-7/8” 38-7/8” 39-7/8” 40-7/8” 41-7/8” 42-7/8” 43-7/8”
EXTERNAL BLOWER ELECTRICAL CONNECTIONS
Blower connection at hood:
1. Run 2-wire plus ground power cable from
the Exterior or In-Line Blower to the hood’s
wiring box marked “motor connection”.
2. Remove the cover from the wiring box and
remove one knockout.
3. Feed 6” of cable through the knockout
opening and secure the cable to the wiring
box with an appropriate connector.
4. Make electrical connections at the hood.
Connect white-to-white, red-to-black and
green-to-ground.
5. Replace the wiring box cover and screws.
make sure wires are not pinched between
the cover and box.
Exterior or In-line blower connection:
1. Make electrical connections at the exterior
or in-line blower (see instructions provided
with the exterior or in-line blower).
Power connection at hood:
1. Plug the power cord into the electrical wall
receptacle.
BLOWER CONNECTION AT HOOD
BOX MARKED
“MOTOR
CONNECTION”
CONNECT:
WHITE-TO-WHITE,
RED-TO-BLACK,
GREEN-TO-GROUND.
Exterior or
In-Line blower
120 VOLT 60 HZ
GROUNDED WALL
OUTLET OFFSET
FROM DUCT CENTER
LINE . (STAY WITHIN
5½” DIMENSION)
19½”
to
20½”
5½”
11”
CENTERLINE
OF HOOD
25
1
/
8
”
18
5
/
8
”
CENTERLINE