Installation Guide

- 14 -
DUCTED INSTALLATION ONLY
Note: Rooms with 10 or 11 foot ceiling
require fl ue extension model AEWC345I-
QSB, available from your local dealer.
Discard the upper fl ue supplied with
the range hood and replace it with thw
longer fl ue extension.
1. Remove protective tape from blower outlet
before installing damper to hood with
(4) screws supplied and tape joint with
aluminum duct tape (Fig.14).
2. Run 8-inch diameter metal ductwork to the
outside location.
3. Install an appropriate wall or roof cap with
damper to exhaust the air to the outside.
4. Tape all duct joints with aluminum duct
tape.
5. Plug power cord into wall outlet (Fig.15).
6. Install upper and lower decorative ues onto
the range hood.
- Vents are concealed on 8-foot ceilings.
- Vents maybe exposed on 9-foot ceilings.
7. Secure upper ue to ue mounting bracket
with (2) 3.9 x 6 mm screws (Fig.16).
8-INCH DIA.
METAL DUCT
FIG. 14
FIG. 16
3.9 x 6 mm
SCREWS
DAMPER / DUCT
CONNECTOR
FIG. 15
CEILING
CONCEALED
VENTS