HB0103 WTT32I Series In USA - BEST® Hartford, Wisconsin REGISTER YOUR PRODUCT ONLINE AT : www.BestRangeHoods.com/register For additional Information visit www.BestRangeHoods.
READ AND SAVE THESE INSTRUCTIONS ! INTENDED FOR DOMESTIC COOKING ONLY ! WARNING TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSON(S) OBSERVE THE FOLLOWING: 1. Use this unit only in the manner intended by the manufacturer. If you have questions, contact the manufacturer at the address or telephone number listed in the warranty. 2. Before servicing or cleaning unit, switch power off at service panel and lock service disconnecting means to prevent power from being switch on accidentally.
TO REDUCE THE RISK OF A RANGE TOP GREASE FIRE: a) Never leave surface units unattended at high settings. Boilovers cause smoking and greasy spillovers that may ignite. Heat oils slowly on low or medium settings. b) Always turn hood ON when cooking at high heat or when cooking flaming foods (i.e. Crêpes Suzette, Cherries Jubilee, Peppercorn Beef Flambé). c) Clean ventilating fans frequently. Grease should not be allowed to accumulate on fan or filters. d) Use proper pan size.
OPERATION Always turn your hood on before you begin cooking to establish an air flow in the kitchen. Let the blower run for a few minutes to clear the air after you turn off the range. The hood is operated using the push buttons on the front panel. HC0023 A. A B C D DELAY SWITCH When a blower speed is selected, press this switch to activate the delay function. The delay button will illuminate to indicate this function is activated.
MAKE-UP AIR DAMPER The hood is compatible with Broan Make-Up Air Damper Model MD6T or Model MD8T (optional). Purchase separately. MAKE-UP AIR DAMPER MAKE UP DAMPER CONNECTION (switched low voltage) 20 GAUGE BELL WIRE FOR LOW VOLTAGE CONNECTION ON TOP OF HOOD 24V TRANSFORMER (INCLUDED) HOOD GRD 120 VAC 60 HZ DRY CONTACT TERMINAL BUSHING FOR LOW VOLTAGE CONNECTION Make the connection to the Make-Up Air Damper with low voltage wiring, as shown.
CLEANING & MAINTENANCE For performance, appearance, and health reasons, clean filter, fan and grease-laden surfaces regularly. Use only a clean cloth and mild detergent solution on stainless and painted surfaces. Clean all-metal filters in the dishwasher using a non-phosphate detergent. Discoloration of the filter may occur if using phosphate detergents, or as a result of local water conditions but this will not affect filter performance. This discoloration is not covered by the warranty.
MEASURE THE INSTALLATION ROOF CAP ROOF CAP ROUND ELBOW ROUND ELBOW 10” ROUND DUCT 8” ROUND DUCT WALL CAP WALL CAP DECORATIVE FLUE DECORATIVE FLUE HOOD MOUNTING BRACKET HOOD MOUNTING BRACKET 4 3/8” FROM WALL TO 6 9/16” FROM WALL TO CENTER LINE OF DUCT CENTER LINE OF DUCT 13 1/8” TO CENTER DECORATIVE FLUE HOOD 12 1/8” TO CENTER DECORATIVE FLUE OF UPPER MOUNTING HOLES HOOD 3 24” TO 30” ABOVE OF UPPER MOUNTING HOLES 3 1 /8” TO CENTER OF LOWER HOOD CHASSIS HOLES 24” TO 30” ABOVE COOKING
PREPARE THE HOOD Unpack hood and check contents.
INSTALL THE WIRING HO CENTEOD RLINE 43/4” (30”, 3 6”, & 4 2” mod 73/4” els) (48” m odel) 24” MAX. 123/8” 24” TO 3 ABO 6” COOKVE TOP GROUNDING INSTRUCTIONS This appliance must be grounded. In the event of an electrical short circuit, grounding reduces the risk of electric shock by providing an escape wire for the electric current. This appliance is equipped with a cord having a grounding wire with a grounding plug. The plug must be plugged into an outlet that is properly installed and grounded.
INSTALL THE HOOD MOUNTING SUPPORT 1. Construct structural wall framing that is flush with interior surface of wall studs. Make sure the framing is centered over installation location. NOTE Hood distance above cooktop is: Minimum 24”, Maximum 30”. 9-ft. and 10-ft. ceilings may require Flue Extension, Model AEWTT32SB (for 30”, 36” & 42” wide hoods) or Model AEWTT328SB (for 48” wide hoods), depending on installation height (purchase separately). See charts below for additional installation height information.
For 48-in.
INSTALL THE HOOD (Ducted Hoods Only) Ceiling Center of installation C L Upper flue mounting bracket slots Flush with the ceiling 1. Center the flue mounting bracket over the hood location and flush with the ceiling. Secure the upper flue bracket to the wall using (2) 4mm x 38mm mounting screws. Note: Drywall anchors may be required (not included). 2. Tighten the screws completely. Make sure that the bracket is tight against the wall and ceiling. 3.
8. Align the two outer keyhole slots on the hood with the mounting screws that were partially tightened into the wall framing. Ensure that hood is seated entirely on mounting screws and that hood is level. Then tighten screws completely. 9. Install (2) 4mm x 38mm long screws into the holes inside the hood and tighten them securely. 10. Reinstall grease filters by aligning rear filter tabs with slots in the hood. Pull down the metal latch tab, push filters into position and release.
13. Slide the upper decorative flue section into the lower decorative flue section. NOTE For ducted applications, the louvers on the upper flue should be hidden by positioning the louvers down, inside of the lower flue. 14. Carefully place the upper/lower flue assembly into the recessed area of the hood. 15. Slide the upper flue upward until it is aligned with its mounting bracket. The bracket should be inside the flue.
INSTALL THE HOOD (Non-Ducted Hoods Only) NON-DUCT KIT MODEL ANKWTT320 OR ANKWTT326 CONTENTS NOTE Non-ducted installations require Non-Duct Kit, Model ANKWTT320 (for 30” wide hood) or Model ANKWTT326 (for 36” or 42” wide hood). NON-DUCT PLENUM ASSEMBLY 2 MOUNTING SCREWS (4mm x 38mm Cross Recessed Pan Head) 8 FILTER CLIPS NON-DUCTED RECIRCULATION FILTERS FLEXIBLE DUCT 1. Center the non-duct Ceiling plenum over the hood location and flush with the ceiling.
8. Align the two outer keyhole slots on the hood with the mounting screws that were partially tightened into the wall framing. Ensure that hood is seated entirely on mounting screws and that hood is level. Then tighten screws completely. 9. Install (2) 4mm x 38mm long screws into the holes inside the hood and tighten them securely. 10. Attach nonducted filters to grease filter using (8) filter clips. 11. Reinstall grease/ non-duct filter assembly by aligning rear filter tab with slots in the hood.
NON-DUCT 8” ROUND PLENUM FLEXIBLE METAL DUCT DUCT LENGTH DECORATIVE FLUE DAMPER / DUCT CONNECTOR 12. Measure and install section of flexible metal ductwork (included with ANKWTT320 or ANKWTT326) to damper/duct connector and bottom of nonduct plenum. Use duct tape to make all joints secure and air tight. CAUTION Do not use plastic duct. 13. Plug power cord into wall outlet. 14. Slide the upper decorative flue section into the lower decorative flue section.
SERVICE PARTS 30”, 36” & 42” Wide Models KEY PART NO.
SERVICE PARTS 30”, 36” & 42” Wide Models 13 1 12 1 11 6 10 5 Replacement parts can be ordered on our website: www.BestRangeHoods.
SERVICE PARTS 48” Wide Model KEY PART NO. DESCRIPTION QTY.
SERVICE PARTS 48” Wide Model 1 11 1 6 Replacement parts can be ordered on our website: www.BestRangeHoods.
WARRANTY ONE YEAR LIMITED WARRANTY FOR BEST PRODUCTS Broan-NuTone LLC (Broan-NuTone) warrants to the original consumer purchaser of Best products that such products will be free from defects in materials or workmanship for a period of one year from the date of original purchase. THERE ARE NO OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING, BUT NOT LIMITED TO, IMPLIED WARRANTIES OR MERCHANT ABILITY OR FITNESS FOR A PARTICULAR PURPOSE.