4.1 High temp.life test
Temperature +85 °C
Duration 100hrs
4.2 Low temp.life test
Temperature -40 °C
Duration 100hrs
4.3 Temperature cycle test
Cycles 10
4.4 Humidity Test
Temperature +40 °C
Relative Humidity 90~95%
Duration 48hrs
Tests above should be measured after leaving normal temperature for 6hrs.
4.5 Vibration Test
Vibration Frequency 10~55Hz
Amplitude 1.52mm/min
Direction 3(x.y&z)
Duration 2hrs each cycle(total 6 hrs)
4.6 Drop test
Height 1m
(Dropped to 20mm thick hardwood board without packing.)
Direction 3
4.7 Soldering Heat Shock
Temperature 260 ±5°c
Duration 2 ±0.5 sec
4.8 Terminal Mechanical Strength
Strength 1kg
Duration 1 min
Notice:
All specifications must be satisfied in this condition.
Sensitivity :Allowable deviation within ±3dB from initial sensitivity.
BCM4520OSF-42
4.Reliability Test
1hrs
+85 C
1hrs 1hrs1hrs
+20 C+20 C
-40 C
BCM4520OSF-42
Microphone
Page:3 of 5
DRG NO:
B/TEM01.119A
A
Rev. Drawn
Approved by:
Note
Checked by:
Drawn by:
Date:
王焕焕
Date
王焕焕
A
10.06.27
10.06.27