4.5 Temperature Cycle Test
Cycles 6
4.3 Low Temperature Test
Temperature -20±2°C
Duration 24hrs
4.1 Load Test
Power (Nom) 1.0W(sine wave)
Duration 24hrs
4.4 Damp Heat
Temperature 40±2°C
Relative Humidity 90%-95%RH
Duration 24hrs
4.2 High Temperature Test
Temperature +75±2°C
Duration 24hrs
This print and information there in are proprietary to Bestar Electronics Industry Co., Ltd.
and shall not be used in whole or in part without its written content
D
C
E
F
G
D
C
E
F
G
46 5 3 2 1
4.6 Drop Test
Height 1.0m
Drop face thick board (20mm)
Times 10
4.Reliability Test
李红元
王文邦
A
王文邦
Acoustics & Sensor
2010/12/28
2010/12/28
BLS1530-11-08H3.5 LF
DRG NO: BS/TES01.1086A
BLS1530-11-08H3.5 LF
+25
-20
T(°C)
+75
t (min)
30
1 cycles
30 30
transition time:20-30s
3.Sensitivity difference at 0.8~2KHz shall be within ±3dB from initial value after test.
Notice:
1.Immediately after reliability test,the samples shall be stored under climatic conditions
such as normally exist in ordinary rooms or laboratories.Unless otherwise noted,the
recovery period shall be 2hrs at least before performance testing.
2. After reliability test ,all samples must be meet the requirements specified