User guide

4.1 Low temperature test
Temperature -30°C
Duration 98hrs
4.2 High temperature test
Temperature +70°C
Duration 98hrs
4.3 Humidity test
Temperature +40°C
Humidity 95%RH
Duration 98hrs
4.4 Durability test
Duration Testing after 1000hours actual continuous operation
4.5 Shock withstanding
High 75cm to ground
4.6 Vibration test
Cycles 2000 cycles per minute
Amplitude 2mm
Directions x,y,z three direction for 30min each
www.be-star.com wu@be-star.com
This print and information there in are proprietary to Bestar Electronics Industry Co., Ltd.
and shall not be used in whole or in part without its written content
6 5 4
Drawn
REV.
A
Date
B
Note
Drawn by:
Approved by:
Checked by:
Date:
C
4.1-4.3 Should be measured after 2hrs exposed in normal temperature,
after each of test,no abnormality shall exist.
D
E
F
F/HU110P24VIP67-M LF
4.Reliability Test
G
H
6 5 4
Page:4 of 6
DRG NO: BS/TEP01.076B
3 2 1
Piezo Siren
A
B
C
D
E
F
G
H
3 2 1
F/HU110P24VIP67-M LF
10/03/02
B
廖明才
程久生
陈小东
廖明才
10/03/02