Owners manual

1 2084-120841 with GFCI - 2015
1. READ ALL INSTRUCTIONS CAREFULLY and get a thorough understanding of what is required to assemble your Type
RP Power Filter.
2. Before you begin to assemble the pool, identify, count, and check all parts needed for assembly.
3. It is recommended that you have some PETROLEUM JELLY on hand for lubricating the gaskets.
1. Installer shall follow written instructions provided for operation of the circulation systems.
2. All electrical components shall be installed in accordance with Article 680 of the National Electrical Code (NEC) “Swim-
ming Pools, Fountains and Similar Installations” or its latest approved edition.
3. The Filter Cartridge (15) 3-3/4” will hold as many as 2 of the 1” diameter chlorine tablets and the 8” will hold as many as
6 of the 1” diameter chlorine tablets. Check your chlorine levels to determine the proper number of chlorine tablets to
add. The filter cartridge will automatically dispense chlorine into the pool as the pump runs.
You must have the type of Filter Cartridge (15) with a central core mesh divider (See page 3) to use the chlorine
dispenser. DO NOT use this to dispense powdered chlorine, shock treatment or any other type of chemicals as
damage to the pump, filter cartridge, and pool will occur.
4. The RP Type pump/filter systems are manufactured by Polygroup and ETL control number 4000608 - double insulated
and grounded - 115 V.A.C. - 60 Hz. (ALL Units must have a minimum of 105 V.A.C. to start and run properly.)
PRELIMINARY STEPS
POWER FILTER IMPORTANT NOTES:
2X
4X
F1000C / F1500C / F2000C
F700C
Press
"RESET"
Button
To Start
Pump
Operation
How to use the GFCI plug:
*Do not connect
to a timer device
RP TYPE SWIMMING POOL FILTER SYSTEM
OWNER’S MANUAL FOR ABOVE
GROUND SWIMMING POOLS
DISTRIBUTED BY: POLYGROUP LIMITED (MCO)
To order parts, accessories, or answers to frequently asked questions
about your product please visit WWW.POLYGROUPSTORE.COM
Customer Service: (888) 919-0070
To watch how to setup your product please visit:
WWW.POLYGROUP.COM/VIDEO
DO NOT RETURN PRODUCT TO STORE
Avenida Xian Xing Hai, Centro Golden Dragon, 11 Andar M, Macau
IMPORTANT SAFETY INSTRUCTIONS
1. POWER FILTER INSTALLATION
2. PUMP OPERATION
3. PUMP MOTOR PROTECTION
4. FILTER CARTRIDGE CLEANING INSTRUCTIONS
5. POOL MAINTENANCE
6. POOL WATER CARE
7. TROUBLE SHOOTING GUIDE
8. POWER FILTER DISASSEMBLY AND STORAGE
PARTS LIST
ASME COMPLIANT SUCTION FITTING INFO
2
4
5
5
5
6
6
7
8
9
10
Do not bury cord. Locate cord to minimize abuse from lawn mowers, hedge trimmers, and other equipment.
The unit is provided with a ground-fault circuit-interrupter (GFCI). To test the GFCI, push the test button. The GFCI should
interrupt power. Push the reset button. Power should be restored. If the GFCI fails to operate in this manner, the GFCI is
defective. If the GFCI interrupts power to the pump without the test button being pushed, a ground current is flowing,
indicating the possibility of an electric shock. Do not use this pump. Disconnect the pump and have the problem
corrected by a qualified service representative before using.
SAVE THESE INSTRUCTIONS
IMPORTANT SAFETY INSTRUCTIONS
When installing and using this electrical equipment, basic safety precautions
should always be followed, including the following:
READ AND FOLLOW ALL INSTRUCTIONS
WARNING - To reduce the risk of injury, do not permit children to use this product
unless they are closely supervised at all times.
WARNING - Risk of Electric Shock. Connect only to a grounding type receptacle. This
product is provided with a ground-fault circuit-interrupter. If replacement of the plug or
cord is needed, use only identical replacement parts.
WARNING - To reduce the risk of electric shock, replace damaged cord
immediately.
WARNING - To reduce the risk of electric shock, do not use extension cord to
connect unit to electric supply; provide a properly located outlet.
CAUTION - To reduce the risk of electric shock the pool must be installed no closer
than 6 feet (1.8 m) from any electrical outlet. Do not place portable appliances closer
than 5 feet (1.5 m) from the pool.
CAUTION - This pump is for use with storable pools only. Do not use with
permanently-installed pools. A storable pool is constructed so that it is capable of being
readily disassembled for storage and reassembled to its original integrity. A
permanently-installed pool is constructed in or on the ground or in a building such that
it cannot be readily disassembled for storage.
Should you encounter a problem with your Polygroup Product, please do not return the product to the
place or purchase. All Warranty claims must be made directly to Polygroup. Prior to contacting Cus-
tomer Service, please first review the Troubleshooting Guide in the Installation Manual, or review the
FAQ at www.polygroup.com. Please review setup instruction videos on www.polygroup.com/video. If
you are still unable to correct the problem, please contact Polygroup customer service at (888) 919-
0070. Have the product type and your purchase receipt ready. Our Customer Service Representative
will assist you in resolving the problem. You may be asked to return all or part of the product for
inspection and/or repair. Do not return any product to Polygroup without a Return Authorization
number.

Summary of content (5 pages)